Article (Scientific journals)
Clinical Value of CT-Based 3D Computational Modeling in Left Atrial Appendage Occlusion: An In-Depth Analysis of the PRECISE LAAO Study.
De Cock, Emmanuel; Lochy, Stijn; Rivero-Ayerza, Maximo et al.
2025In Catheterization and Cardiovascular Interventions
Peer Reviewed verified by ORBi
 

Files


Full Text
100171449.pdf
Publisher postprint (1.23 MB)
Download

All documents in ORBi are protected by a user license.

Send to



Details



Keywords :
LAA closure; MSCT; atrial fibrillation; clinical research; computational modeling
Abstract :
[en] [en] BACKGROUND: Standard of care (SoC) assessment based on computed tomography (CT) and/or transesophageal echocardiography is suboptimal for adequate preprocedural evaluation for left atrial appendage occlusion (LAAO). This can be improved through CT-based 3D computational modeling of the LAA-device interaction using FEops HEARTguide. This study aims to assess the decisional impact of FEops in preprocedural planning for LAAO. METHODS: The PRECISE LAAO is a prospective multi-center self-controlled study evaluating the use of FEops in LAAO with Amulet. Preprocedural device size selection and degree of certainty (scale 0-10) were registered before (Decision SoC) and after accessing FEops (Decision FEops), followed by device implantation. Concordance was compared between the Decisions and the final implanted device. After the procedure, clinicians rated the subjective value of FEops on a scale from -3 (futile) to +3 (most helpful). RESULTS: One hundred two patients were included. Decision SoC was concordant with the implanted device in 61 patients (59.8%), whereas Decision FEops was concordant in 92 (90.2%, p < 0.0001). FEops induced a size change in 35 patients, which was correct in 33 (32.4%). Certainty SoC was 6.7 ± 1.3 and increased after FEops assessment to 7.6 ± 1.3 (p < 0.0001). In the 33 patients with FEops-induced positive corrections, Certainty SoC was lower (6.2 ± 1.5, suggesting a more complex procedure) and increased to 7.2 ± 1.2 with FEops (p = 0.004). Clinicians rated FEops as helpful (subjective score ≥ 1) in 90.2% of cases. CONCLUSIONS: CT-based computational modeling using FEops has a positive decisional impact in LAAO, inducing a change in Amulet size selection in almost one out of three patients and increasing procedural confidence. Trials Trial Registration: NCT04640051.
Disciplines :
Cardiovascular & respiratory systems
Author, co-author :
De Cock, Emmanuel ;  Department of Cardiology, AZ Sint-Jan Brugge AV, Brugge, Belgium ; Department of Cardiology, Ghent University Hospital, Ghent, Belgium
Lochy, Stijn;  Department of Cardiology, UZ Brussel, Brussel, Belgium
Rivero-Ayerza, Maximo;  Department of Cardiology, Ziekenhuis Oost-Limburg (ZOL), Genk, Belgium
Lempereur, Mathieu  ;  Université de Liège - ULiège > Département des sciences cliniques
Cornelis, Kristoff;  Department of Cardiology, AZ Maria Middelares, Gent, Belgium
Debonnaire, Philippe;  Department of Cardiology, AZ Sint-Jan Brugge AV, Brugge, Belgium
Vermeersch, Paul ;  Department of Cardiology, ZNA Middelheim, Antwerpen, Belgium
Christiaen, Emma;  Department of Cardiology, AZ Sint-Jan Brugge AV, Brugge, Belgium
Buysschaert, Ian;  Department of Cardiology, AZ Sint-Jan Brugge AV, Brugge, Belgium
Language :
English
Title :
Clinical Value of CT-Based 3D Computational Modeling in Left Atrial Appendage Occlusion: An In-Depth Analysis of the PRECISE LAAO Study.
Publication date :
24 February 2025
Journal title :
Catheterization and Cardiovascular Interventions
ISSN :
1522-1946
eISSN :
1522-726X
Peer reviewed :
Peer Reviewed verified by ORBi
Available on ORBi :
since 25 February 2025

Statistics


Number of views
72 (0 by ULiège)
Number of downloads
68 (0 by ULiège)

Scopus citations®
 
2
Scopus citations®
without self-citations
2
OpenCitations
 
0
OpenAlex citations
 
2

Bibliography


Similar publications