Article (Scientific journals)
Recent advances in devices for mechanical thrombectomy.
Blanc, Raphaël; Escalard, Simon; Baharvadhat, Humain et al.
2020In Expert Review of Medical Devices, 17 (7), p. 697 - 706
Peer Reviewed verified by ORBi
 

Files


Full Text
blanc2020.pdf
Publisher postprint (677.3 kB)
Request a copy

All documents in ORBi are protected by a user license.

Send to



Details



Keywords :
A direct first pass aspiration technique (ADAPT); Balloon Guide Catheter (BGC); Mechanical Thrombectomy (MT); TICI score; emboli in new territory (ENT); first pass effect (FPE); intra venous thrombolysis (IVT); large vessel occlusion (LVO); stent retriever (SR); Brain Ischemia/complications; Brain Ischemia/surgery; Catheters; Humans; Stents; Stroke/complications; Stroke/surgery; Thrombectomy/instrumentation; Thrombectomy/trends; Treatment Outcome; Acute ischemic stroke; Class A; Current practices; Emerging technologies; Expert opinion; Level-1; Mechanical thrombectomy; Meta analysis; Brain Ischemia; Stroke; Thrombectomy; Surgery; Biomedical Engineering
Abstract :
[en] [en] INTRODUCTION: Acute ischemic stroke (AIS) secondary to the occlusion of a large intracranial vessel (LVO) is a recognized public health problem. Mechanical thrombectomy (MT) has gained full acceptance: Class A, Level 1 in 2015 after the publication of numerous trials. Further meta-analyses have scrutinized extensively those results and international recommendations and guidelines have been given. Nevertheless, multiple-specific points remain to be clarified and are or will be under investigations. AREAS COVERED: This review of the most recent literature (mostly publications after 2015) will cover the actual common practice for MT, especially focusing on the devices available (and their validation), how they are commonly used, relate the most relevant results, and detail some emerging technologies. EXPERT OPINION: The authors will express their own view on the current practice and emphasize on the areas where questions remain and hypothesize what specific improvements are necessary and prone to occur.
Disciplines :
Neurology
Author, co-author :
Blanc, Raphaël ;  Interventional Neuroradiology Department, Fondation Rothschild Hospital , Paris, France ; Université Paris Denis Diderot, Sorbonne Paris Cite , Paris, France ; Laboratory of Vascular Translational Science, U1148 Institut National de la Santé et de la Recherche Médicale (INSERM) , Paris, France
Escalard, Simon;  Interventional Neuroradiology Department, Fondation Rothschild Hospital , Paris, France
Baharvadhat, Humain;  Interventional Neuroradiology Department, Fondation Rothschild Hospital , Paris, France
Desilles, Jean Philippe;  Interventional Neuroradiology Department, Fondation Rothschild Hospital , Paris, France ; Université Paris Denis Diderot, Sorbonne Paris Cite , Paris, France ; Laboratory of Vascular Translational Science, U1148 Institut National de la Santé et de la Recherche Médicale (INSERM) , Paris, France
Boisseau, William;  Interventional Neuroradiology Department, Fondation Rothschild Hospital , Paris, France
Fahed, Robert ;  Department of Medicine/Division of Neurology, Department of Medical Imaging/Division of Radiology, The Ottawa Hospital , Ottawa, Ontario, Canada
Redjem, Hocine;  Interventional Neuroradiology Department, Fondation Rothschild Hospital , Paris, France
Ciccio, Gabriele;  Interventional Neuroradiology Department, Fondation Rothschild Hospital , Paris, France
Smajda, Stanislas;  Interventional Neuroradiology Department, Fondation Rothschild Hospital , Paris, France
Maier, Benjamin;  Interventional Neuroradiology Department, Fondation Rothschild Hospital , Paris, France
Delvoye, François  ;  Université de Liège - ULiège > Département des sciences cliniques ; Interventional Neuroradiology Department, Fondation Rothschild Hospital , Paris, France
Hebert, Solène;  Interventional Neuroradiology Department, Fondation Rothschild Hospital , Paris, France
Mazighi, Mikael;  Interventional Neuroradiology Department, Fondation Rothschild Hospital , Paris, France ; Université Paris Denis Diderot, Sorbonne Paris Cite , Paris, France ; Laboratory of Vascular Translational Science, U1148 Institut National de la Santé et de la Recherche Médicale (INSERM) , Paris, France
Piotin, Michel;  Interventional Neuroradiology Department, Fondation Rothschild Hospital , Paris, France ; Université Paris Denis Diderot, Sorbonne Paris Cite , Paris, France ; Laboratory of Vascular Translational Science, U1148 Institut National de la Santé et de la Recherche Médicale (INSERM) , Paris, France
More authors (4 more) Less
Language :
English
Title :
Recent advances in devices for mechanical thrombectomy.
Publication date :
July 2020
Journal title :
Expert Review of Medical Devices
ISSN :
1743-4440
eISSN :
1745-2422
Publisher :
Taylor and Francis Ltd., England
Volume :
17
Issue :
7
Pages :
697 - 706
Peer reviewed :
Peer Reviewed verified by ORBi
Available on ORBi :
since 25 November 2024

Statistics


Number of views
9 (0 by ULiège)
Number of downloads
0 (0 by ULiège)

Scopus citations®
 
20
Scopus citations®
without self-citations
19
OpenCitations
 
16
OpenAlex citations
 
24

Bibliography


Similar publications



Contact ORBi