Laboratory medicine & medical technology Urology & nephrology
Author, co-author :
Mohamed, Abdulfataah A A ; Department of Internal Medicine, Division of Nephrology, University Medical Center Groningen, Groningen, The Netherlands
Bökenkamp, Arend; Department of Pediatric Nephrology, Emma Children's Hospital, Amsterdam University Medical Centers, Amsterdam, The Netherlands
Cavalier, Etienne ; Université de Liège - ULiège > Département de pharmacie > Chimie médicale
Delanaye, Pierre ; Université de Liège - ULiège > Département de pharmacie > Chimie médicale ; Service de Néphrologie-Dialyse-Aphérèse, Hôpital Universitaire Carémeau, Nîmes, France
Ebert, Natalie ; Charité-Universitätsmedizin Berlin, Institute of Public Health, Berlin, Germany
van Londen, Marco ; Department of Internal Medicine, Division of Nephrology, University Medical Center Groningen, Groningen, The Netherlands
Language :
English
Title :
Diverse protocols for measuring glomerular filtration rate using iohexol clearance.
Stevens LA, Levey AS. Measured GFR as a confirmatory test for estimated GFR. J Am Soc Nephrol 2009;20:2305–13. https://doi.org/10.1681/ASN.2009020171
Kidney Disease: Improving Global Outcomes CKD Work Group. KDIGO clinical practice guideline for the evaluation and management of chronic kidney disease. Kidney Int Suppl 2013;3:1–150.
Carrara F, Gaspari F. GFR measured by iohexol: the best choice from a laboratory perspective. J Lab Precis Med 2018;3:77. https://doi.org/10.21037/jlpm.2018.09.07
Nordin G, Ekvall S, Kristoffersson C et al. Accuracy of determination of the glomerular filtration marker iohexol by European laboratories as monitored by external quality assessment. Clin Chem Lab Med 2019;57:1006–11. https://doi.org/10.1515/cclm-2018-1175
Bosch JP, Saccaggi A, Lauer A et al. Renal functional reserve in humans. Effect of protein intake on glomerular filtration rate. Am J Med 1983;75:943–50. https://doi.org/10.1016/0002-9343(83) 90873-2
van Acker BA, Koomen GC, Koopman MG et al. Discrepancy between circadian rhythms of inulin and creatinine clearance. J Lab Clin Med 1992;120:400–10.
Koopman MG, Koomen GCM, Krediet RT et al. Circadian rhythm of glomerular filtration rate in normal individuals. Clin Sci 1989;77:105–11. https://doi.org/10.1042/ cs0770105
Ebert N, Loesment A, Martus P et al. Iohexol plasma clearance measurement in older adults with chronic kidney disease-sampling time matters. Nephrol Dial Transplant 2015;30:1307–14. https://doi.org/10.1093/ndt/gfv116
Stolz A, Hoizey G, Toupance O et al. Evaluation of sample bias for measuring plasma iohexol clearance in kidney transplantation. Transplantation 2010;89:440–5. https://doi.org/10.1097/TP. 0b013e3181ca7d1b
Delanaye P, Flamant M, Dubourg L et al. Single- versus multiple-sample method to measure glomerular filtration rate. Nephrol Dial Transplant 2018;33:1778–85. https://doi.org/10.1093/ndt/gfx345
Speeckaert MM, Seegmiller J, Glorieux G et al. Measured glomerular filtration rate: the query for a workable golden standard technique. J Pers Med 2021;11:949. https://doi.org/10.3390/ jpm11100949
Pottel H, Hoste L, De Waele L et al. Measuring glomerular filtration rate using 51Cr-EDTA. Nucl Med Commun 2014;35:1150–5. https://doi.org/10.1097/MNM.0000000000000186