Reliability and difference in neck extensor muscles strength measured by a portable dynamometer in individuals with and without chronic neck pain(1).pdf
[en] [en] OBJECTIVE: There are limited reports about the reliability of measuring neck extensor muscle strength using a portable dynamometer in neck pain patients. The aims of the current study were 1) to investigate intra- and inter-rater reliability of neck extensor isometric strength measurement using a portable dynamometer in patients with chronic nonspecific neck pain (CNSNP) and 2) to compare neck extensor isometric strength in participants with and without CNSNP.
METHODS: Guidelines for Reporting Reliability and Agreement Studies (GRRAS) were followed. Two examiners received a 15-minute training before enrollment. Inter-rater reliability was assessed with a 10-minute interval between measurements, and intra-rater reliability was assessed with a 10-day interval. Three trials were assessed and examiners were blind to the strength values (in Newtons) from other sessions of 20 individuals with CNSNP (mean±SD= 37.9 ± 9.8y; Neck Disability Index 29.2 ± 7.4%) and 20 individuals with other musculoskeletal disorders (mean ± SD = 32.8 ± 46.2y).
RESULTS: Intra-rater reliability was excellent with intraclass correlation coefficient (ICC)(3,1) of 0.95 (CI:0.90-0.97) and inter-rater reliability was good to excellent with ICC(2,1) of 0.88 (CI:0.77-0.94) in CNSNP. No significant difference of neck extensor strength was found between CNSNP (93.27N±31.94) and Individuals without CNSNP (111.43N±40.11) (p > 0.05).
CONCLUSION: A portable dynamometer is a reliable tool for measuring maximal isometric neck extension strength in individuals with CNSNP. Slightly but no significant differences of neck extensor strength values between individuals with and without CNSNP. Future studies are needed to assess the generalizability of the findings in patients with other muscle deconditioning.
Disciplines :
Orthopedics, rehabilitation & sports medicine
Author, co-author :
Grondin, Francis; Laboratoire IRISSE, UFR Des Sciences de l'Homme Et de l'Environnement, Université de La Réunion, La Réunion, France ; School of Physiotherapy (IFMK de la Réunion), Centre Hospitalier Universitaire de La Réunion, Reunion, France
Colman, David ; Université de Liège - ULiège > Département des sciences de la motricité > Kinésithérapie spécifique et réadaptation motrice
Peyrot, Nicolas; Laboratoire IRISSE, UFR Des Sciences de l'Homme Et de l'Environnement, Université de La Réunion, La Réunion, France ; Le Mans Université, Mouvement - Interactions - Performance, MIP, EA 43 34, F-72000 Le Mans, France
Maillard, Olivier; Centre for Clinical Investigation (CIC 1410) Institut National de la Santé et de la Recherche Médicale (INSERM), Centre Hospitalier Universitaire de La Réunion, Saint Pierre, Reunion
Freppel, Sébastien; Neurosurgery Department, Centre Hospitalier Universitaire de La Réunion, Reunion, France
Caderby, Teddy; Laboratoire IRISSE, UFR Des Sciences de l'Homme Et de l'Environnement, Université de La Réunion, La Réunion, France
Perdrix, Yannick ; School of Physiotherapy (IFMK de la Réunion), Centre Hospitalier Universitaire de La Réunion, Reunion, France
Language :
English
Title :
Reliability and difference in neck extensor muscles strength measured by a portable dynamometer in individuals with and without chronic neck pain.
GBD. Disease and injury incidence and prevalence collaborators. Global, regional, and national incidence, prevalence, and years lived with disability for 310 diseases and injuries, 1990-2015: a systematic analysis for the global burden of disease study 2015. Lancet. 2015 [2015 Oct8]; 388 (10053): 1545–602. 2.
Cagnie B, Cools A, De Loose V, et al. Differences in isometric neck a reliable measurement. Arch Phys Med Rehabil. 2007 Nov; 88 (11): 1441–1445.
Pearson I, Reichert A, De Serres SJ, et al. Maximal voluntary isometric neck strength deficits in adults with whiplash-associated disorders and association with pain and fear of movement. J Orthop Sports Phys Ther. 2009 Mar; 39 (3): 179–187.
De Pauw R, Coppieters I, Kregel J, et al. Does muscle morphology change in chronic neck pain patients? - A systematic review. Man Ther. 2016 Apr; 22: 42–49.
Gross A, Kay TM, Paquin J-P, et al. Exercises for mechanical neck disorders. Cochrane Database Syst Rev. 2015Jan28; CD004250 1: 10.1002/14651858.CD004250.pub5.
Schneider KJ, Leddy JJ, Guskiewicz KM, et al. Rest and treatment/rehabilitation following sport-related concussion: a systematic review. Br J Sports Med. 2017 Jun; 51 (12): 930–934.
de Koning CH, van Den Heuvel SP, Staal JB, et al. Clinimetric evaluation of methods to measure muscle functioning in patients with non-specific neck pain: a systematic review. BMC Musculoskelet Disord. 2008 Oct 19; 9 (1): 142.
O’Leary S, Fagermoen CL, Hasegawa H, et al. Differential strength and endurance parameters of the craniocervical and cervicothoracic extensors and flexors in healthy individuals. J Appl Biomech. 2017 Apr; 33 (2): 166–170. Epub 2016 Nov11.
Ylinen J, Salo P, Nykänen M, et al. Decreased isometric neck strength in women with chronic neck pain and the repeatability of neck strength measurements. Arch Phys Med Rehabil. 2004 Aug; 85 (8): 1303–1308.
Scheuer R, Friedrich M. Reliability of isometric strength measurements in trunk and neck region: patients with chronic neck pain compared with pain-free persons. Arch Phys Med Rehabil. 2010 Dec; 91 (12): 1878–1883.
Chiu TTW, Sing KL. Evaluation of cervical range of motion and isometric neck muscle strength: reliability and validity. Clin Rehabil. 2002 Dec; 16 (8): 851–858.
Salmon DM, Handcock PJ, Sullivan SJ, et al. Can neck strength be measured using a single maximal contraction in a simulated contact position? J Strength Cond Res. 2018 Aug; 32 (8): 42–49.
Chkeir A, Jaber R, Hewson DJ, et al. Estimation of grip force using the Grip-ball dynamometer. Med Eng Phys. 2013 Nov; 35 (11): 1698–1702.
Romero-Franco N, Fernández-Domínguez JC, Montaño-Munuera JA, et al. Validity and reliability of a low-cost dynamometer to assess maximal isometric strength of upper limb. J Sports Sci. 2019 Aug; 37 (15): 1787–1793.
Selistre LFA, de S MC, de NMA. Reliability and validity of clinical tests for measuring strength or endurance of cervical muscles: a systematic review and meta-analysis. Arch Phys Med Rehabil. 2021 Jun; 102 (6): 1210–1227.
Kottner J, Audigé L, Brorson S, et al. Guidelines for Reporting Reliability and Agreement Studies (GRRAS) were proposed. J Clin Epidemiol. 2011 Jan; 64 (1): 96–106.
Koo TK, Li MY. A guideline of selecting and reporting intraclass correlation coefficients for reliability research. J Chiropr Med. 2016 Jun; 15 (2): 155–163.
Bruton A, Conway JH, Holgate ST. Reliability: what is it, and how is it measured? Physiotherapy. 2000 Feb 1; 86 (2): 94–99.
Geary K, Green BS, Delahunt E. Intrarater reliability of neck strength measurement of rugby union players using a handheld dynamometer. J Manipulative Physiol Ther. 2013 Sep; 36 (7): 444–9.
Kubas C, Chen Y-W, Echeverri S, McCann SL, Denhoed MJ, Walker CJ, et al. Reliability and Validity of Cervical Range of Motion and Muscle Strength Testing. J Strength Cond Res. avr 2017; 31 (4): 1087–96.
Vannebo KT, Iversen VM, Fimland MS, Mork PJ. Test-retest reliability of a handheld dynamometer for measurement of isometric cervical muscle strength. J Back Musculoskelet Rehabil. 2018; 31 (3): 557–65.
Tudini F, Myers B, Bohannon R. Reliability and validity of measurements of cervical retraction strength obtained with a hand-held dynamometer. J Man Manip Ther. 2019 Sep; 27 (4): 222–8.
Krause DA, Hansen KA, Hastreiter MJ, Kuhn TN, Peichel ML, Hollman JH. A Comparison of Various Cervical Muscle Strength Testing Methods Using a Handheld Dynamometer. Sports Health. 2019 Feb; 11 (1): 59–63.
Carnevalli AP de O, Bevilaqua-Grossi D, Oliveira AIS, Carvalho GF, Fernández-De-Las-Peñas C, Florencio LL. Intrarater and Inter-rater Reliability of Maximal Voluntary Neck Muscle Strength Assessment Using a Handheld Dynamometer in Women With Headache and Healthy Women. J Manipulative Physiol Ther. 2018 Sep; 41 (7): 621–7.
Shahidi B, Johnson CL, Curran-Everett D, Maluf KS. Reliability and group differences in quantitative cervicothoracic measures among individuals with and without chronic neck pain. BMC Musculoskelet Disord. 2012Oct31; 13: 215.
Ordway NR, Seymour RJ, Donelson RG, Hojnowski LS, Edwards WT. Cervical flexion, extension, protrusion, and retraction. A radiographic segmental analysis. Spine (Phila Pa 1976). 1999Feb1; 24 (3): 240–7
Ghamkhar L, Arab AM, Nourbakhsh MR, Kahlaee AH, Zolfaghari R. Examination of Regional Interdependence Theory in Chronic Neck Pain: Interpretations from Correlation of Strength Measures in Cervical and Pain-Free Regions. Pain Med. 2020Feb1; 21 (2): e182–90.
Li DE, David KEB, O’Leary S, Treleaven J. Higher variability in cervical force perception in people with neck pain. Musculoskelet Sci Pract. 2019 Jul; 42: 6–12.
Lindstroem R, Graven-Nielsen T, Falla D. Current pain and fear of pain contribute to reduced maximum voluntary contraction of neck muscles in patients with chronic neck pain. Arch Phys Med Rehabil. 2012 Nov; 93 (11): 2042–8.
Harms-Ringdahl K, Schüldt K. Maximum neck extension strength and relative neck muscular load in different cervical spine positions. Clin Biomech (Bristol, Avon). 1989 Feb; 4(1): 17–24