Simulation of a geothermal aquifer storage in Brussels showing the need for a better balanced system with regards to the local hydrogeological conditions
[en] An Aquifer Thermal Energy Storage (ATES) system was started in 2014 in the center of Brussels using the Landenian confined aquifer for heat and cold needs of an administrative building. Unfortunately, the imbalance between the injection of warm and cold water combined with the local hydrogeological conditions, has led rapidly to thermal interferences between the heat plume and the cold wells. A second ATES system located nearby started to operate around August 2017 for the heat and cold needs of another large administrative building. In the scope of the MUSE project (GeoERA/ERA-NET program), a numerical model was built using FEFLOW® to simulate groundwater flow and heat transport in the confined aquifer. After calibration on the available piezometric and temperature data, realistic scenarios were simulated to determine possible interferences and to image the year after year persisting and growing heat plume in the aquifer. Results show that even if the heat plumes of the two systems had come into contact, the influence of the second system on the first one was negligible during the first two years of joint operation. Indeed, for a longer period, simulated results pointed out that due to the thermal imbalance and the limited advection in the aquifer, the groundwater temperature would rise inexorably in the warm and cold wells of both systems. A business as usual scenario will lead to a decrease in efficiency for both systems. This case-study is showing how it could be difficult to find an optimum with regards to the local hydrogeological conditions. If advection is very important, thermal energy cannot actually be stored locally as heat and cold plumes are transported far away from the wells. On the contrary, if advection is limited, a global thermal balance is required for hot and cold injections. If advection is moderate (as in this case study), a detailed simulation of the groundwater flow and heat transport in the aquifer is required to find out if the annual imbalance can be managed in relation to the specific local hydrogeological conditions.
Disciplines :
Geological, petroleum & mining engineering
Author, co-author :
Bulté, Manon; AQUALE Ltd Environmental Protection > former Master Student in Geological Engineering at University of Liège
Petitclerc, Estelle; Royal Belgian Institute of Natural Sciences > Geological Survey of Belgium > Geothermal Energy
Agniel, Mathieu; Brussels Environment > Water Dpt
Dassargues, Alain ; Université de Liège - ULiège > Département ArGEnCo > Hydrogéologie & Géologie de l'environnement
Language :
English
Title :
Simulation of a geothermal aquifer storage in Brussels showing the need for a better balanced system with regards to the local hydrogeological conditions
This website uses cookies to improve user experience. Read more
Save & Close
Accept all
Decline all
Show detailsHide details
Cookie declaration
About cookies
Strictly necessary
Performance
Strictly necessary cookies allow core website functionality such as user login and account management. The website cannot be used properly without strictly necessary cookies.
This cookie is used by Cookie-Script.com service to remember visitor cookie consent preferences. It is necessary for Cookie-Script.com cookie banner to work properly.
Performance cookies are used to see how visitors use the website, eg. analytics cookies. Those cookies cannot be used to directly identify a certain visitor.
Used to store the attribution information, the referrer initially used to visit the website
Cookies are small text files that are placed on your computer by websites that you visit. Websites use cookies to help users navigate efficiently and perform certain functions. Cookies that are required for the website to operate properly are allowed to be set without your permission. All other cookies need to be approved before they can be set in the browser.
You can change your consent to cookie usage at any time on our Privacy Policy page.