Agarwal, R., Delanaye, P., Glomerular filtration rate: when to measure and in which patients?. Nephrol Dial Transplant 34 (2019), 2001–2007.
Delanaye, P., Melsom, T., Ebert, N., et al. Iohexol plasma clearance for measuring glomerular filtration rate in clinical practice and research: a review. Part 2: Why to measure glomerular filtration rate with iohexol?. Clin Kidney J 9 (2016), 700–704.
Delanaye, P., Ebert, N., Melsom, T., et al. Iohexol plasma clearance for measuring glomerular filtration rate in clinical practice and research: a review. Part 1: How to measure glomerular filtration rate with iohexol ?. Clin Kidney J 9 (2016), 682–699.
Soveri, I., Berg, U.B., Björk, J., et al. Measuring GFR: a systematic review. Am J Kidney Dis 64 (2014), 411–424.
Delanaye, P., Dubourg, L., Flamant, M., et al. Comparison of early-compartment correction equations for GFR measurements. Kidney Int Rep 5 (2020), 1079–1081.
Chantler, C., Barratt, T.M., Estimation of glomerular filtration rate from plasma clearance of 51-chromium edetic acid. Arch Dis Child 47 (1972), 613–617.
Brochner-Mortensen, J., A simple method for the determination of glomerular filtration rate. Scand J Clin Lab Invest 30 (1972), 271–274.
Fleming, J.S., Zivanovic, M.A., Blake, G.M., et al. Guidelines for the measurement of glomerular filtration rate using plasma sampling. Nucl Med Commun 25 (2004), 759–769.
Jodal, L., Brochner-Mortensen, J., Jodal, L., et al. Reassessment of a classical single injection 51Cr-EDTA clearance method for determination of renal function in children and adults. Part I: Analytically correct relationship between total and one-pool clearance. Scand J Clin Lab Invest 69 (2009), 305–313.
Ng, D.K., Schwartz, G.J., Jacobson, L.P., et al. Universal GFR determination based on two time points during plasma iohexol disappearance. Kidney Int 80 (2011), 423–430.
Dubourg, L., Lemoine, S., Joannard, B., et al. Comparison of iohexol plasma clearance formulas vs. inulin urinary clearance for measuring glomerular filtration rate. Clin Chem Lab Med 59 (2020), 571–579.
Flamant, M., Vidal-Petiot, E., Metzger, M., et al. Performance of GFR estimating equations in African Europeans: basis for a lower race-ethnicity factor than in African Americans. Am J Kidney Dis 62 (2013), 182–184.
Sterner, G., Frennby, B., Mansson, S., et al. Determining “true” glomerular filtration rate in healthy adults using infusion of inulin and comparing it with values obtained using other clearance techniques or prediction equations. Scand J Urol Nephrol 42 (2008), 278–285.
Stehlé, T., El Karoui, K., Sakka, M., et al. Creatinine clearance after cimetidine administration in a new short procedure: comparison with plasma and renal clearances of iohexol. Clin Kidney J 13 (2020), 587–596.
White, C.A., Akbari, A., Allen, C., et al. Simultaneous glomerular filtration rate determination using inulin, iohexol and 99mTc-DTPA demonstrates the need for customized measurement protocols. Kidney Int 99 (2021), 957–966.
Rouanne, M., Gaillard, F., Meunier, M., et al. Measured glomerular filtration rate (GFR) significantly and rapidly decreases after radical cystectomy for bladder cancer. Sci Rep, 10, 2020, 16145.
Pottel, H., Hoste, L., De Waele, L., et al. Measuring glomerular filtration rate using 51Cr-EDTA: body surface area normalization before or after Bröchner-Mortensen correction?. Nucl Med Commun 35 (2014), 1150–1155.
Blake, G.M., Barnfield, M.C., Burniston, M.T., et al. Measuring glomerular filtration rate using chromium-51 EDTA: body surface area normalization before or after Brøchner-Mortensen correction?. Nucl Med Commun 36 (2015), 295–300.
Lin, L., A concordance correlation coefficient to evaluate reproducibility. Biometrics 45 (1989), 255–268.
Bland, J.M., Altman, D.G., Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 327 (1986), 307–310.
Delanaye, P., Flamant, M., Dubourg, L., et al. Single- versus multiple-sample method to measure glomerular filtration rate. Nephrol Dial Transplant 33 (2018), 1778–1785.
Stehlé, T., El Karoui, K., Audard, V., et al. Comparison of iohexol plasma clearances calculated from 5 early-compartment correction equations with urinary clearance of iohexol. Kidney Int Rep 5 (2020), 1842–1843.
Cavalier, E., Rozet, E., Dubois, N., et al. Performance of iohexol determination in serum and urine by HPLC: validation, risk and uncertainty assessment. Clin Chim Acta 396 (2008), 80–85.
Agarwal, R., Ambulatory GFR measurement with cold iothalamate in adults with chronic kidney disease. Am J Kidney Dis 41 (2003), 752–759.
Stolz, A., Hoizey, G., Toupance, O., et al. Evaluation of sample bias for measuring plasma iohexol clearance in kidney transplantation. Transplantation 89 (2010), 440–445.
Fleming, J.S., An improved equation for correcting slope-intercept measurements of glomerular filtration rate for the single exponential approximation. Nucl Med Commun 28 (2007), 315–320.
Skluzacek, P.A., Szewc, R.G., Nolan, C.R. III, et al. Prediction of GFR in liver transplant candidates. Am J Kidney Dis 42 (2003), 1169–1176.
Brandstrom, E., Grzegorczyk, A., Jacobsson, L., et al. GFR measurement with iohexol and 51Cr-EDTA. A comparison of the two favoured GFR markers in Europe. Nephrol Dial Transplant 13 (1998), 1176–1182.
Delanaye, P., Jouret, F., Le Goff, C., et al. Concordance between iothalamate and iohexol plasma clearance. Am J Kidney Dis 68 (2016), 329–330.