Article (Scientific journals)
Low-dose CT for the spatial normalization of PET images: A validation procedure for amyloid-PET semi-quantification.
Presotto, Luca; Iaccarino, Leonardo; Sala, Arianna et al.
2018In NeuroImage: Clinical, 20, p. 153-160
Peer Reviewed verified by ORBi
 

Files


Full Text
1-s2.0-S2213158218302250-main.pdf
Publisher postprint (1.47 MB)
Request a copy

All documents in ORBi are protected by a user license.

Send to



Details



Keywords :
Aged; Aged, 80 and over; Alzheimer Disease/diagnostic imaging; Brain/diagnostic imaging; Databases, Factual; Female; Humans; Magnetic Resonance Imaging/methods/standards; Male; Middle Aged; Plaque, Amyloid/diagnostic imaging; Positron Emission Tomography Computed Tomography/methods/standards; Positron-Emission Tomography/methods/standards; Prodromal Symptoms; Radiation Dosage; Reproducibility of Results; Tomography, X-Ray Computed/methods/standards; Alzheimer's disease; Amyloid burden; Positron emission tomography/computed tomography; SUVr
Abstract :
[en] The reference standard for spatial normalization of brain positron emission tomography (PET) images involves structural Magnetic Resonance Imaging (MRI) data. However, the lack of such structural information is fairly common in clinical settings. This might lead to lack of proper image quantification and to evaluation based only on visual ratings, which does not allow research studies or clinical trials based on quantification. PET/CT systems are widely available and CT normalization procedures need to be explored. Here we describe and validate a procedure for the spatial normalization of PET images based on the low-dose Computed Tomography (CT) images contextually acquired for attenuation correction in PET/CT systems. We included N = 34 subjects, spanning from cognitively normal to mild cognitive impairment and dementia, who underwent amyloid-PET/CT ((18)F-Florbetaben) and structural MRI scans. The proposed pipeline is based on the SPM12 unified segmentation algorithm applied to low-dose CT images. The validation of the normalization pipeline focused on 1) statistical comparisons between regional and global (18)F-Florbetaben-PET/CT standardized uptake value ratios (SUVrs) estimated from both CT-based and MRI-based normalized PET images (SUVr(CT,) SUVr(MRI)) and 2) estimation of the degrees of overlap between warped gray matter (GM) segmented maps derived from CT- and MRI-based spatial transformations. We found negligible deviations between regional and global SUVrs in the two CT and MRI-based methods. SUVr(CT) and SUVr(MRI) global uptake scores showed negligible differences (mean ± sd 0.01 ± 0.03). Notably, the CT- and MRI-based warped GM maps showed excellent overlap (90% within 1 mm). The proposed analysis pipeline, based on low-dose CT images, allows accurate spatial normalization and subsequent PET image quantification. A CT-based analytical pipeline could benefit both research and clinical practice, allowing the recruitment of larger samples and favoring clinical routine analysis.
Disciplines :
Radiology, nuclear medicine & imaging
Author, co-author :
Presotto, Luca
Iaccarino, Leonardo
Sala, Arianna  ;  UniSR
Vanoli, Emilia G.
Muscio, Cristina
Nigri, Anna
Bruzzone, Maria Grazia
Tagliavini, Fabrizio
Gianolli, Luigi
Perani, Daniela
Bettinardi, Valentino
Language :
English
Title :
Low-dose CT for the spatial normalization of PET images: A validation procedure for amyloid-PET semi-quantification.
Publication date :
2018
Journal title :
NeuroImage: Clinical
eISSN :
2213-1582
Publisher :
Elsevier, Netherlands
Volume :
20
Pages :
153-160
Peer reviewed :
Peer Reviewed verified by ORBi
Available on ORBi :
since 02 June 2021

Statistics


Number of views
37 (2 by ULiège)
Number of downloads
1 (1 by ULiège)

Scopus citations®
 
20
Scopus citations®
without self-citations
16
OpenCitations
 
14

Bibliography


Similar publications



Contact ORBi