Biomagnetism; Electric fields; Electromagnetic field effects; Errors; Numerical methods; Systematic errors; Average errors; Body-worn sensors; Correction formulas; Electric and magnetic fields; Incident fields; Measurement methodology; Measurement techniques; Reference values; Wearable sensors
Abstract :
[en] Objective: As well known, using a single body worn sensor exposimeter introduces systematic errors on the measurement of the incident free space electric field strength. This is because the body creates around it high, intermediate and low level field zones, which depend on the direction of arrival of the incident field. The goal of this work is to propose an efficient method for the reduction of these errors. Methods: After classifying the perturbations induced by the body on the measured electric and magnetic fields thanks to realistic numerical simulations, we then propose a two-sensor setup in conjunction with simple semi-empirical correction formulas, in order to compensate these perturbations. Results: At 942 MHz, when the two sensors are placed in any opposite sides of the body at chest height, the worst case, maximum and average errors respectively decrease to 12% and 3% compared to 83% and 22% for measurement techniques using a single sensor, or 32% and 11% when using the average value of the measurements. Conclusion: The error related to the measurement in the presence of the body was significantly reduced by the proposed method making use of two opposite sensors, E-field and H-field at the chest. Significance: The conformity of exposure to EMF in terms of reference values according to the ICNIRP is given in the abscence of the human body. The interest of this work lies in the reduction of the errors made when measuring the field in the presence of the body.
Disciplines :
Electrical & electronics engineering
Author, co-author :
Kwate, R. K.; Electronic and Systems Laboratory, Faculty of Sciences, Mohammed Premier University, Oujda, Morocco
Elmagroud, Bachir; Electronic and Systems Laboratory, Faculty of Sciences, Mohammed Premier University, Oujda, Morocco
Taybi, Chakib; Electronic and Systems Laboratory, Faculty of Sciences, Mohammed Premier University, Oujda, Morocco
Beauvois, Véronique ; Université de Liège - ULiège > Dép. d'électric., électron. et informat. (Inst.Montefiore) > Dép. d'électric., électron. et informat. (Inst.Montefiore)
Geuzaine, Christophe ; Université de Liège - ULiège > Dép. d'électric., électron. et informat. (Inst.Montefiore) > Applied and Computational Electromagnetics (ACE)
Picard, Dominique; DRE, Signals and Systems Laboratory, CentraleSupelec, Paris, France
Ziyyat, Abdelhak; Electronic and Systems Laboratory, Faculty of Sciences, Mohammed Premier University, Oujda, Morocco
Language :
English
Title :
Measurement methodologies for reducing errors in the assessment of EMF by exposimeter
Publication date :
2017
Journal title :
Progress in Electromagnetics Research B
eISSN :
1937-6472
Publisher :
Electromagnetics Academy
Volume :
78
Pages :
31-46
Peer reviewed :
Peer Reviewed verified by ORBi
Funders :
MOHE - Ministry of Higher Education EGU - European Geosciences Union
ICNIRP, "Guidelines for limiting exposure to time-varying electric, magnetic and electromagnetic fields (up to 300GHz)," Health Physics, Vol. 74, No. 4, 494, 522, 1998
De Miguel-Bilbao, S., J. Garca, V. Ramos, and J. Blas, "Assessment of human body influence on exposure measurements of electric field in indoor enclosures," Bioelectromagnetics, Vol. 36, No. 2, 118-132, 2015
De Miguel-Bilbao, S., V. Ramos, and J. Blas, "Assessment of polarization dependence of body shadow effect on dosimetry measurements in 2.4GHz band," Bioelectromagnetics, Vol. 38, No. 4, 315-321, 2017
Krzysztof, G., Z. Patryk, and K. Jolanta, "The role of the location of personal exposimeters on the human body in their use for assessing exposure to the electromagnetic field in the radiofrequency range 982450 MHz and compliance analysis: Evaluation by virtual measurements," BioMed Research International, Vol. 2015, 2015
Iskra, S., R. McKenzie, and I. Cosic, "Monte carlo simulations of the electric field close to the body in realistic environments for application in personal radiofrequency dosimetry," Radiation Protection Dosimetry, Vol. 147, No. 4, 517, 2011
Gallastegi, M., M. Guxens, A. Jim'enez-Zabala, I. Calvente, M. Fern'andez, L. Birks, B. Struchen, M. Vrijheid, M. Estarlich, M. F. Fern'andez, M. Torrent, F. Ballester, J. J. Aurrekoetxea, J. Ibarluzea, D. Guerra, J. Gonz'alez, M. Röösli, and L. Santa-Marina, "Characterisation of exposure to non-ionising electromagnetic fields in the spanish inma birth cohort: Study protocol," BMC Public Health, Vol. 16, No. 1, 167, 2016
Cansiz, M., T. Abbasov, M. Bahattin Kurt, and A. Recai Celik, "Mapping of radio frequency electromagnetic field exposure levels in outdoor environment and comparing with reference levels for general public health," J. Expos. Sci. Environ. Epidemiol., Original Article, Nov. 2016
Neubauer, G., S. Cecil, W. Giczi, B. Petric, P. Preiner, J. Frhlich, and M. Rsli, "The association between exposure determined by radiofrequency personal exposimeters and human exposure: A simulation study," Bioelectromagnetics, Vol. 31, No. 7, 535-545, 2010
Roblin, C. and A. Sibille, "Measurement of a body-worn triaxial sensor for electromagnetic field and exposure assessment," 2014 8th European Conference on Antennas and Propagation (EuCAP), 2631-2635, Apr. 2014
Blas, J., F. A. Lago, P. Fernndez, R. M. Lorenzo, and E. J. Abril, "Potential exposure assessment errors associated with body-worn RF dosimeters," Bioelectromagnetics, Vol. 28, No. 7, 573-576, 2007
Bahillo, A., J. Blas, P. Fernndez, R. M. Lorenzo, S. Mazuelas, and E. J. Abril, "E-field assessment errors associated with RF dosemeters for different angles of arrival," Radiation Protection Dosimetry, Vol. 132, No. 1, 51-56, 2008
Iskra, S., R. McKenzie, and I. Cosic, "Personal, non-invasive dosimetry for radio-frequency human exposure assessment," 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 2319-2322, Aug. 2007
Thielens, A., H. De Clercq, S. Agneessens, J. Lecoutere, L. Verloock, F. Declercq, G. Vermeeren, E. Tanghe, H. Rogier, R. Puers, L. Martens, and W. Joseph, "Personal distributed exposimeter for radio frequency exposure assessment in real environments," Bioelectromagnetics, Vol. 34, No. 7, 563-567, 2013
Weiland, T., "A discretization method for the solution of maxwells equations for six-component fields," Electronics and Communications AEU, Vol. 31, No. 3, 116-120, 1977
Clemens, M. and T. Weiland, "Discrete electromagnetism with the finite integration technique," Progress In Electromagnetics Research, Vol. 32, 65-87, 2001
Petoussi-Henss, N., M. Zankl, U. Fill, and D. Regulla, "The GSF family of voxel phantoms," Physics in Medicine and Biology, Vol. 47, No. 1, 89, 2002
Iskra, S., R. McKenzie, and I. Cosic, "Factors influencing uncertainty in measurement of electric fields close to the body in personal rf dosimetry," Radiation Protection Dosimetry, Vol. 140, No. 1, 25-33, 2010
Kwate Kwate, R., B. Elmagroud, C. Taybi, D. Picard, and A. Ziyyat, "Interaction between human body and personal radiofrequency dosimeter: Effects of the metal plate presence," Proc. IEEE 14th Edition of the Mediterranean Microwave Symposium MMS14, Marrakech, Morocco, Dec. 12-14, 2014
Kwate Kwate, R., B. Elmagroud, C. Taybi, V. Beauvois, Ch. Geuzaine, D. Picard, and A. Ziyyat, "On calibration of correction law for EMF measurement errors due to the proximity of the human body," Proc. IEEE 15th edition of the Mediterranean Microwave Symposium MMS15, 1-4, Lecce, Italy, 2015
Elmagroud, B., R. Kwate Kwate, C. Taybi, D. Picard, and A. Ziyyat, "Electromagnetic exposure assessment for telecommunication equipements using RF dosimeter," Proc. IEEE 2nd International Conference on Information Technology for Organizations Development, IT4OD-2016, Fez, Morocco, 2016