Details



Keywords :
F18; FDG; Medipix; Nuclear detector; PET; Positron; Radiopharmaceutical; Timepix; Chemical detection; Electrons; Gamma rays; Polyethylene terephthalates; Positrons; Radiation; Conventional detectors; Nuclear detectors; Pharmaceutical production; Quantitative comparison; Very high dynamic ranges; Radioactivity; Article
Abstract :
[en] Current techniques for the measurement of radioactivity at various points during PET radiopharmaceutical production and R&D are based on the detection of the annihilation gamma rays from the radionuclide in the labelled compound. The detection systems to measure these gamma rays are usually variations of NaI or CsF scintillation based systems requiring costly and heavy lead shielding to reduce background noise. These detectors inherently suffer from low detection efficiency, high background noise and very poor linearity. They are also unable to provide any reasonably useful position information. A novel positron counting technique is proposed for the radioactivity assay during radiopharmaceutical manufacturing that overcomes these limitations. Detection of positrons instead of gammas offers an unprecedented level of position resolution of the radiation source (down to sub-mm) thanks to the nature of the positron interaction with matter. Counting capability instead of charge integration in the detector brings the sensitivity down to the statistical limits at the same time as offering very high dynamic range and linearity from zero to any arbitrarily high activity. This paper reports on a quantitative comparison between conventional detector systems and the proposed positron counting detector. © 2017 The Authors
Disciplines :
Physical, chemical, mathematical & earth Sciences: Multidisciplinary, general & others
Author, co-author :
Maneuski, D.;  SUPA School of Physics and Astronomy, University of Glasgow, Glasgow, United Kingdom
Giacomelli, Fabrice ;  Université de Liège - ULiège > Centre de recherches du cyclotron
Lemaire, Christian ;  Université de Liège - ULiège > Centre de recherches du cyclotron
Pimlott, S.;  School of Medicine, University of Glasgow, Glasgow, United Kingdom
Plenevaux, Alain  ;  Université de Liège - ULiège > Département de chimie (sciences) > Département de chimie (sciences)
Owens, J.;  PET Radiopharmaceutical Production Unit, Gartnavel General Hospital, Glasgow, United Kingdom
O'Shea, V.;  SUPA School of Physics and Astronomy, University of Glasgow, Glasgow, United Kingdom
Luxen, André ;  Université de Liège - ULiège > Centre de recherches du cyclotron
Language :
English
Title :
On the use of positron counting for radio-Assay in nuclear pharmaceutical production
Publication date :
2017
Journal title :
Applied Radiation and Isotopes
ISSN :
0969-8043
Publisher :
Elsevier Ltd
Volume :
125
Pages :
9-14
Peer reviewed :
Peer Reviewed verified by ORBi
Available on ORBi :
since 23 March 2018

Statistics


Number of views
72 (6 by ULiège)
Number of downloads
114 (1 by ULiège)

Scopus citations®
 
8
Scopus citations®
without self-citations
8
OpenCitations
 
7

Bibliography


Similar publications



Contact ORBi