[1] Akoumianaki, E, Maggiore, SM, Valenza, F, Bellani, G, Jubran, A, Loring, SH, et al. The application of esophageal pressure measurement in patients with respiratory failure. Am J Respir Crit Care Med 189:5 (2014), 520–531.
[3] Akoumianaki, E, Lyazidi, A, Rey, N, Matamis, D, Perez-Martinez, N, Giraud, R, et al. Mechanical ventilation-induced reverse-triggered breaths: a frequently unrecognized form of neuromechanical coupling. Chest 143:4 (2013), 927–938.
[4] Talmor, D, Sarge, T, Malhotra, A, O'Donnell, CR, Ritz, R, Lisbon, A, et al. Mechanical ventilation guided by esophageal pressure in acute lung injury. N Engl J Med 359:20 (2008), 2095–2104.
[5] Talmor, D, Sarge, T, O'Donnell, CR, Ritz, R, Malhotra, A, Lisbon, A, et al. Esophageal and transpulmonary pressures in acute respiratory failure. Crit Care Med 34:5 (2006), 1389–1394.
[7] Bellemare, P, Goldberg, P, Magder, S, Variations in pulmonary artery occlusion pressure to estimate changes in pleural pressure. Intensive Care Med 33:11 (2007), 2004–2008.
[9] Magder, S, Diagnostic information from the respiratory variations in central hemodynamics pressures. Scharf, S.M., Pinsky, M.R., Magder, S., (eds.) Respiratory-circulatory interactions in health and disease, 2001, Marcel Dekker, Inc., New York, 861–882.
[11] West, JB, Dollery, CT, Naimark, A, Distribution of blood flow in isolated lungs: relation to vascular and alveolar pressures. J Appl Physiol 19 (1964), 713–724.
[12] Permutt, S, Bromberger-Barnea, B, Bane, HN, Alveolar pressure, pulmonary venous pressure, and the vascular waterfall. Med Thorac 19 (1962), 239–260.
[13] Teboul, JL, Besbes, M, Andrivet, P, Axler, O, Douget, D, Zelter, M, et al. A bedside index assessing the reliability of pulmonary artery occlusion pressure measurements during mechanical ventilation with positive end-expiratory pressure. J Crit Care 7:1 (1992), 22–29.
[14] Roy, R, Powers, SR, Feustel, PJ, Dutton, RE, Pulmonary wedge catheterization during positive end-expiratory pressure ventilation in the dog. Anesthesiology 46:6 (1977), 385–390.
[15] Tooker, J, Huseby, J, Butler, J, The effect of swan-Ganz catheter height on the wedge pressure-left atrial pressure relationships in edema during positive-pressure ventilation. Am Rev Respir Dis 117:4 (1978), 721–725.
[16] Jardin, F, Farcot, JC, Boisante, L, Carien, N, Margairaz, A, Bourdarias, JP, Influence of positive end-expiratory pressure on left ventricular performance. N Engl J Med 304 (1981), 387–392.
[17] Jardin, F, Vieillard-Baron, A, Right ventricular function and positive pressure ventilation in clinical practice: from hemodynamic subsets to respirator settings. Intensive Care Med 29:9 (2003), 1426–1434.
[18] Vieillard-Baron, A, Loubieres, Y, Schmitt, JM, Page, B, Dubourg, O, Jardin, F, Cyclic changes in right ventricular output impedance during mechanical ventilation. J Appl Physiol 87:5 (1999), 1644–1650.
[19] Howell, JB, Permutt, S, Proctor, DF, Riley, RL, Effect of inflation of the lung on different parts of pulmonary vascular bed. J Appl Physiol 16 (1961), 71–76.
[20] Magder, SA, Lichtenstein, S, Adelman, AG, Effects of negative pleural pressure on left ventricular hemodynamics. Am J Cardiol 52:5 (1983), 588–593.
[21] Permutt, S, Howell, JBL, Proctor, DF, Riley, RL, Effect of lung inflation on static pressure volume characteristics of pulmonary vessels. J Appl Physiol 16 (1961), 64–70.
[22] Magder, S, Lagonidis, D, Erice, F, The use of respiratory variations in right atrial pressure to predict the cardiac output response to PEEP. J Crit Care 16:3 (2002), 108–114.
[24] Asher, MI, Coates, AL, Collinge, JM, Milic-Emili, J, Measurement of pleural pressure in neonates. J Appl Physiol Respir Environ Exerc Physiol 52:2 (1982), 491–494.
[25] Saldiva, PH, Cardoso, WV, Caldeira, MP, Zin, WA, Mechanics in rats by end-inflation occlusion and single-breath methods. J Appl Physiol (1985) 63:5 (1987), 1711–1718.
[26] Sousa, AS, Moll, RJ, Pontes, CF, Saldiva, PH, Zin, WA, Mechanical and morphometrical changes in progressive bilateral pneumothorax and pleural effusion in normal rats. Eur Respir J 8:1 (1995), 99–104.
[27] Flemale, A, Gillard, C, Dierckx, JP, Comparison of central venous, oesophageal and mouth occlusion pressure with water-filled catheters for estimating pleural pressure changes in healthy adults. Eur Respir J 1:1 (1988), 51–57.
[28] Talmor, DS, Fessler, HE, Are esophageal pressure measurements important in clinical decision-making in mechanically ventilated patients?. Respir Care 55:2 (2010), 162–172.
[29] Beda, A, Guldner, A, Carvalho, AR, Zin, WA, Carvalho, NC, Huhle, R, et al. Liquid- and air-filled catheters without balloon as an alternative to the air-filled balloon catheter for measurement of esophageal pressure. PLoS One, 9(9), 2014, e103057.
[30] Magder, S, Guerard, B, Heart-lung interactions and pulmonary buffering: lessons from a computational modeling study. Respir Physiol Neurobiol 182:2–3 (2012), 60–70.