BCR-ABL1; Chronic myelogenous leukaemia; International Scale; standardization; therapy monitoring
Abstract :
[en] INTRODUCTION: Standardization of BCR-ABL1 messenger RNA quantification by real-time PCR on the International Scale (IS) is critical for monitoring therapy response in chronic myelogenous leukaemia. Since 2006, BCR-ABL1 IS standardization is propagated along reference laboratories by calculating a laboratory-specific conversion factor (CF), co-ordinated in Europe through the European Treatment and Outcome Study project. Although this process has proven successful to some extent, it has not been achievable for all laboratories due to the complexity of the process and the stringent requirements in terms of numbers of samples to be exchanged. In addition, several BCR-ABL1 IS quantification methods and secondary reference materials became commercially available. However, it was observed that different IS methods generate consistently different results. METHODS: To overcome these difficulties, we have developed an alternative and simple approach of CF calculation, based on the retrospective analysis of existing external quality assessment (EQA) data. Our approach does not depend on the exchange of samples and is solely based on the mathematical CF calculation using EQA results. RESULTS AND CONCLUSION: We have demonstrated by thorough statistical validation that this approach performs well in converting BCR-ABL1 measurements to improve IS estimation. In expectation of a true golden standard method for BCR-ABL1 IS quantification, the proposed method is a valuable alternative.
Disciplines :
Genetics & genetic processes
Author, co-author :
Maes, B.
Bakkus, M.
Boeckx, N.
Boone, E.
Cauwelier, B.
Denys, B.
De Schouwer, P.
Devos, T.
El Housni, H.
Hillen, F.
Jacobs, K.
LAMBERT, Frédéric ; Centre Hospitalier Universitaire de Liège - CHU > Service de génétique
Baccarani M, Deininger MW, Rosti G, Hochhaus A, Soverini S, Apperley JF, Cervantes F, Clark RE, Cortes JE, Guilhot F, Hjorth-Hansen H, Hughes TP, Kantarjian HM, Kim DW, Larson RA, Lipton JH, Mahon FX, Martinelli G, Mayer J, Müller MC, Niederwieser D, Pane F, Radich JP, Rousselot P, Saglio G, Saußele S, Schiffer C, Silver R, Simonsson B, Steegmann JL, Goldman JM, Hehlmann R. European LeukemiaNet recommendations for the management of chronic myelogenous leukemia: 2013. Blood 2013;122:872–84.
Hughes T, Deininger M, Hochhaus A, Branford S, Radich J, Kaeda J, Baccarani M, Cortes J, Cross NC, Druker BJ, Gabert J, Grimwade D, Hehlmann R, Kamel-Reid S, Lipton JH, Longtine J, Martinelli G, Saglio G, Soverini S, Stock W, Goldman JM. Monitoring CML patients responding to treatment with tyrosine kinase inhibitors: review and recommendations for harmonizing current methodology for detecting BCR-ABL transcripts and kinase domain mutations and for expressing results. Blood 2006;108:28–37.
Hughes TP, Kaeda J, Branford S, Rudzki Z, Hochhaus A, Hensley ML, Gathmann I, Bolton AE, van Hoomissen IC, Goldman JM, Radich JP, and the International Randomised Study of Interferon versus STI571 (IRIS) Study Group. Frequency of major molecular responses to imatinib or interferon alfa plus cytarabine in newly diagnosed chronic myelogenous leukemia. N Engl J Med 2003;349:1423–32.
Branford S, Fletcher L, Cross NC, Müller MC, Hochhaus A, Kim DW, Radich JP, Saglio G, Pane F, Kamel-Reid S, Wang YL, Press RD, Lynch K, Rudzki Z, Goldman JM, Hughes T. Desirable performance characteristics for BCR-ABL measurement on an international reporting scale to allow consistent interpretation of individual patient response and comparison of response rates between clinical trials. Blood 2008;112:3330–8.
Cross NCP, Hochhaus A, Müller MC. Molecular monitoring of chronic myelogenous leukemia: principles and interlaboratory standardisation. Ann Hematol 2015;94:S219–25.
UK NEQAS LI Leucocyte Immunophenotyping BCR-ABL1 Quantification Programme reports from March 2011 to January 2015.
Gabert J, Beillard E, van der Velden VH, Bi W, Grimwade D, Pallisgaard N, Barbany G, Cazzaniga G, Cayuela JM, Cave H, Pane F, Aerts JL, De Micheli D, Thirion X, Pradel V, Gonzalez M, Viehmann S, Malec M, Saglio G, van Dongen JJ. Standardisation and quality control studies of ‘real-time’ quantitative reverse transcriptase polymerase chain reaction of fusion gene transcripts for residual disease detection in leukemia: a Europe against cancer program. Leukemia 2003;17:2318–57.
WHO International Standard: 1st WHO International Genetic Reference Panel for quantitation of BCR-ABL translocation by RQ-PCR: NIBSC code: 09/138: instructions for use (version 4.0, dated 13/12/2012). Potters Bar (UK): National Institute for Biological Standards and Control; 2012. http://www.nibsc.ac.uk/ (accessed 10-05-2016)
Picard RR, Cook RD. Cross-validation of regression models. J Am Stat Assoc 1984;79:575–83.
Hehlmann R, Grimwade D, Simonsson B, Apperley J, Baccarani M, Barbui T, Barosi G, Bassan R, Béné MC, Berger U, Büchner T, Burnett A, Cross NC, de Witte TJ, Döhner H, Dombret H, Einsele H, Engelich G, Foà R, Fonatsch C, Gökbuget N, Gluckman E, Gratwohl A, Guilhot F, Haferlach C, Haferlach T, Hallek M, Hasford J, Hochhaus A, Hoelzer D, Kiladjian JJ, Labar B, Ljungman P, Mansmann U, Niederwieser D, Ossenkoppele G, Ribera JM, Rieder H, Serve H, Schrotz-King P, Sanz MA, Saussele S, European LeukemiaNet. The European LeukemiaNet: achievements and perspectives. Haematologica 2011;96:156–62.
Cross NCP, White HE, Colomer D, Ehrencrona H, Foroni L, Gottardi E, Lange T, Lion T, Machova Polakova K, Dulucq S, Martinelli G, Oppliger Leibundgut E, Pallisgaard N, Barbany G, Sacha T, Talmaci R, Izzo B, Saglio G, Pane F, Müller MC, Hochhaus A. Laboratory recommendations for scoring deep molecular responses following treatment for chronic myelogenous leukemia. Leukemia 2015;29:999–1003.
White HE, Matejtschuk P, Rigsby P, Gabert J, Lin F, Lynn Wang Y, Branford S, Müller MC, Beaufils N, Beillard E, Colomer D, Dvorakova D, Ehrencrona H, Goh HG, El Housni H, Jones D, Kairisto V, Kamel-Reid S, Kim DW, Langabeer S, Ma ES, Press RD, Romeo G, Wang L, Zoi K, Hughes T, Saglio G, Hochhaus A, Goldman JM, Metcalfe P, Cross NC. Establishment of the first World Health Organization International Genetic Reference Panel for quantification of BCR-ABL mRNA. Blood 2010;116:e111–7.
Mauté C, Nibourel O, Réa D, Coiteux V, Grardel N, Preudhomme C, Cayuela JM, GBMHM. Calibration of BCR-ABL1 mRNA quantification methods using genetic reference materials is a valid strategy to report results on the international scale. Clin Biochem 2014;47:1333–6.