Midterm clinical outcome following Edwards SAPIEN or Medtronic Corevalve transcatheter aortic valve implantation (TAVI): Results of the Belgian TAVI registry.
Collas, Valerie M.; Dubois, Christophe; LEGRAND, Victoret al.
2015 • In Catheterization and Cardiovascular Interventions, 86 (3), p. 528-35
[en] OBJECTIVE: To assess midterm (3 years) clinical outcomes of transcatheter aortic valve implantation (TAVI) in Belgium using the Edwards SAPIEN valve or the Medtronic CoreValve transcatheter heart valve (THV). BACKGROUND: Medium and long term follow-up data of both THVs are still relatively scarce, although of great clinical relevance for a relatively new but rapidly expanding treatment modality. Therefore, reporting mid- and long term clinical outcome data, coming from large "real world" national registries, remains contributive. METHODS: Between December 2007 and March 2012, 861 "real world" patients who were not candidates for surgical aortic valve replacement as decided by the local heart teams, underwent TAVI at 23 sites. Eleven sites exclusively used SAPIEN THV (n = 460), while 12 exclusively used CoreValve THV (n = 401). Differences in clinical outcomes by valve system were assessed, according to access route and baseline EuroSCORE risk profile (<10%: low, 10-20%: intermediate and >20%: high risk). RESULTS: Overall cumulative survival at 3 years was 51% for SAPIEN vs. 60% for CoreValve (P = 0.021). In transfemorally treated patients, SAPIEN and CoreValve had similar survival at 3 years for each of the baseline EuroSCORE cohorts (low risk: 72% vs. 76%, P = 0.45; intermediate risk: 62% vs. 59%, P = 0.94; high risk: 48% vs. 53%, P = 0.65). CONCLUSION: Cumulative midterm 3 year survival after transfemoral TAVI in "real world" patients refused for surgery with similar baseline EuroSCORE risk profile is not different between SAPIEN or CoreValve.
Disciplines :
Cardiovascular & respiratory systems
Author, co-author :
Collas, Valerie M.
Dubois, Christophe ; Centre Hospitalier Universitaire de Liège - CHU > Cardiologie
LEGRAND, Victor ; Centre Hospitalier Universitaire de Liège - CHU > Cardiologie
Kefer, Joelle
De Bruyne, Bernard
Dens, Jo
Rodrigus, Inez E.
Herijgers, Paul
Bosmans, Johan M.
Language :
English
Title :
Midterm clinical outcome following Edwards SAPIEN or Medtronic Corevalve transcatheter aortic valve implantation (TAVI): Results of the Belgian TAVI registry.
Publication date :
2015
Journal title :
Catheterization and Cardiovascular Interventions
ISSN :
1522-1946
eISSN :
1522-726X
Publisher :
John Wiley & Sons, Hoboken, United States - New York
Iung B, Cachier A, Baron G, Messika-Zeitoun D, Delahaye F, Tornis P, et al., Decision-making in elderly patients with severe aortic stenosis: Why are so many denied surgery?. Eur Heart J 2005; 26: 2714-2720.
Kodali SK, Williams MR, Smith CR, Svensson LG, Webb JG, Makkar RR, et al., Two-year outcomes after transcatheter or surgical aortic-valve replacement. N Engl J Med 2012; 366: 1686-1695.
Makkar RR, Fontana GP, Jilaihawi H, Kapadia S, Pichard AD, Douglas PS, et al., Transcatheter aortic valve replacement for inoperable severe aortic stenosis. N Engl J Med 2012; 366: 1696-1704.
Adams DH, Popma JJ, Reardon MJ, Yakubov SJ, Coselli JS, Deeb M, et al., Transcatheter aortic valve replacement with a self-expanding prosthesis. N Engl J Med 2014; 370: 1790-1798.
Linke A, Wenaweser P, Gerckens U, Tamburino C, Bosmans J, Bleiziffer S, et al., Treatment of aortic stenosis with a self-expanding transcatheter valve: The international multi-centre ADVANCE study. Eur Heart J 2014; 35: 2672-2684.
Moat NE, Ludman P, de Belder MA, Bridgewater B, Cunningham AD, Young CP, et al., Long-term outcomes after transcatheter aortic valve implantation in high-risk patients with severe aortic stenosis-The UK TAVI (United Kingdom transcatheter aortic valve implantation) registry. J Am Coll Cardiol 2012; 58: 2130-2138.
Bosmans JM, Kefer J, De Bruyne B, Herijgers P, Dubois C, Legrand V, et al., Procedural, 30-day and one year outcome following CoreValve or edwards transcatheter aortic valve implantation: Results of the Belgian national registry. Interact Cardiovasc Thorac Surg 2011; 12: 762-767.
Kappetein AP, Head SJ, Généreux P, Piazza N, van Mieghem NM, Blackstone EH, et al., Updated standardized endpoint definitions for transcatheter aortic valve implantation the valve academic research consortium-2 consensus document. J Am Coll Cardiol 2012; 60: 1438-1454.
Gilard M, Eltchaninoff H, Iung B, Donzeau-Gouge P, Chevreul K, Fajadet J, et al., Registry of transcatheter aortic-valve implantation in high-risk patients. N Engl J Med 2012; 366: 1705-1715.
Chieffo A, Buchanan GL, Van Mieghem NM, Tchetche D, Dumonteil N, Latib A, et al., Transcatheter aortic valve implantation with the Edwards SAPIEN Versus the medtronic CoreValve revalving system Devices. A multicenter collaborative study: The PRAGMATIC Plus initiative (Pooled-Rotterdam-Milano-toulouse in collaboration). J Am Coll Cardiol 2013; 61: 830-836.
Zahn R, Gerckens U, Grube E, Linke A, Sievert H, Eggebrecht H, et al., Transcatheter aortic valve implantation: First results from a multi-centre real-world registry. Eur Heart J 2011; 32: 198-204.
Généreux P, Head SJ, Wood DA, Kodali SK, Williams MR, Paradis JM, et al., Transcatheter aortic valve implantation 10-year anniversary: Review of current evidence and clinical implications. Eur Heart J 2012; 33: 2388-2398.
Toggweiler S, Humphries KH, Lee M, Binder RK, Moss RR, Freeman M, et al., 5-year outcome after transcatheter aortic valve implantation. J Am Coll Cardiol 2013; 61: 413-419.
Sabaté M, Cánovas S, García E, Hernández Antolín R, Maroto L, Hernández JM, et al., Predictores de mortalidad hospitalaria ya medio plazo tras el reemplazo valvular aõrtico transcathéter: Datos del registro nacional TAVI 2010-2011. Rev Esp Cardiol 2013; 66: 949-958.
Abdel-Wahab M, Mehilli J, Frerker C, Neumann FJ, Kurz T, Tölg R, et al., Comparison of balloon-expendable vs. self-expandable valves in patients undergoing transcatheter aortic valve replacement: The CHOICE randomized clinical trial. JAMA 2014; 311: 1503-1514.
Ussia GP, Barbanti M, Petronio AS, Tarantini G, Ettori F, Colombo A, et al., Transcatheter aortic valve implantation: 3-year outcomes of self-expanding CoreValve prosthesis. Eur Heart J 2012; 33: 969-976.
Zahn R, Gerckens U, Linke A, Sievert H, Kahlert P, Hambrecht R, et al., Predictors of one-year mortality after transcatheter aortic valve implantation for severe symptomatic aortic stenosis. Am J Cardiol 2013; 112: 272-279.