Article (Scientific journals)
Correlation and agreement between bispectral index and state entropy of the electroencephalogram during propofol anaesthesia
BONHOMME, Vincent; Deflandre, Eric; Deflandre, Eric
2006In British Journal of Anaesthesia, 97 (3), p. 340-346
Peer Reviewed verified by ORBi
 

Files


Full Text
BIS_SE_propofol_BJA_2006.pdf
Publisher postprint (145.26 kB)
Request a copy

All documents in ORBi are protected by a user license.

Send to



Details



Keywords :
monitoring, bispectral index; monitoring, depth of anaesthesia; monitoring, electroencephalography; monitoring, entropy, statistics, agreement
Abstract :
[en] Background. Bispectral index (BIS) and state entropy (SE) monitor hypnosis. We evaluated the correlation and the agreement between those parameters during propofol anaesthesia and laryngoscopy with and without muscle relaxation. Methods. A total of 25 patients were anaesthetized with propofol. At steady state (SS: BIS 40-50), they randomly received rocuronium (R) or saline (S); 3 min thereafter, a 20 s laryngoscopy was performed. Correlation (regression analysis) and agreement (Bland-Altman analysis) were evaluated before induction (baseline), at loss of eyelash reflex (LER), at SS and during the first 3 min after laryngoscopy (L). Results. The correlation coefficient r (95% CI), the mean difference (MD) (95% CI), and the limits of agreement [lower-upper limits of 95% CI of MD (sd 1.96)] between BIS and SE were as follows. Overall recordings: 0.87 (0.83 to 0.90), 2.5 (1.2 to 3.0), and [-19.5 to 24.6]; Baseline: 0.45 (0.06 to 0.72), 7.6 (6.0 to 9.2), and [-2.7 to 17.9]; LER: 0.74 (0.47 to 0.88), 8.3 (3.5 to 13.2), and [-22.6 to 39.3]; SS, all patients: 0.41 (0.14 to 0.63), 2.0 (-0.5 to 4.6), and [-19.0 to 23.3]; SS, Group S: 0.36 (-0.07 to 0.68), 1.9 (-2.5 to 6.3), and [-25.0 to 28.8]; SS, Group R: 0.63 (0.32 to 0.82), 0.2 (-2.0 to 2.3), and [-14.0 to 14.4]; L, all patients: 0.49 (0.32 to 0.63), 0.7 (-1.6 to 3.0), and [-25.6 to 27.1]; L, Group S: 0.41 (0.13 to 0.63), 2.3 (-2.4 to 7.1), and [-36.7 to 41.3]; L, Group R: 0.72 (0.56 to 0.83), -0.6 (-2.2 to 1.0), and [-14.3 to 13.1]. The correlation was good except for SS in Group S. The MD was significantly different from 0 for overall recordings, during baseline and LER, but not for the other conditions. The agreement was poor except for baseline, and SS and L in Group R. Conclusions. BIS and SE are globally well correlated. In contrast, agreement is poor as differences of more than 20 units are frequently observed, except for awake and paralysed patients.
Disciplines :
Anesthesia & intensive care
Author, co-author :
BONHOMME, Vincent  ;  Centre Hospitalier Universitaire de Liège - CHU > Anesthésie et réanimation
Deflandre, Eric ;  Université de Liège - ULiège > Doct. sc. médicales (Bologne)
Deflandre, Eric;  CHU Liège > Anesthésie-Réanimation
Language :
English
Title :
Correlation and agreement between bispectral index and state entropy of the electroencephalogram during propofol anaesthesia
Publication date :
September 2006
Journal title :
British Journal of Anaesthesia
ISSN :
0007-0912
eISSN :
1471-6771
Publisher :
Oxford University Press, Oxford, United Kingdom
Volume :
97
Issue :
3
Pages :
340-346
Peer reviewed :
Peer Reviewed verified by ORBi
Available on ORBi :
since 13 August 2015

Statistics


Number of views
71 (0 by ULiège)
Number of downloads
2 (1 by ULiège)

Scopus citations®
 
37
Scopus citations®
without self-citations
33
OpenCitations
 
26
OpenAlex citations
 
37

Bibliography


Similar publications



Contact ORBi