Article (Scientific journals)
Expiratory model-based method to monitor ARDS disease state
Van Drunen, EJ; Chiew, YS; Chase, JG et al.
2013In BioMedical Engineering OnLine, 12 (57)
Peer Reviewed verified by ORBi
 

Files


Full Text
van drunen et al. biomed eng online. 2013.pdf
Publisher postprint (3.25 MB)
Download

All documents in ORBi are protected by a user license.

Send to



Details



Keywords :
Mechanical ventilation; Model-based methods; Expiration; ARDS; Intensive care; Time constant
Abstract :
[en] INTRODUCTION: Model-based methods can be used to characterise patient-specific condition and response to mechanical ventilation (MV) during treatment for acute respiratory distress syndrome (ARDS). Conventional metrics of respiratory mechanics are based on inspiration only, neglecting data from the expiration cycle. However, it is hypothesised that expiratory data can be used to determine an alternative metric, offering another means to track patient condition and guide positive end expiratory pressure (PEEP) selection. METHODS: Three fully sedated, oleic acid induced ARDS piglets underwent three experimental phases. Phase 1 was a healthy state recruitment manoeuvre. Phase 2 was a progression from a healthy state to an oleic acid induced ARDS state. Phase 3 was an ARDS state recruitment manoeuvre. The expiratory time-constant model parameter was determined for every breathing cycle for each subject. Trends were compared to estimates of lung elastance determined by means of an end-inspiratory pause method and an integral-based method. All experimental procedures, protocols and the use of data in this study were reviewed and approved by the Ethics Committee of the University of Liege Medical Faculty. RESULTS: The overall median absolute percentage fitting error for the expiratory time-constant model across all three phases was less than 10 %; for each subject, indicating the capability of the model to capture the mechanics of breathing during expiration. Provided the respiratory resistance was constant, the model was able to adequately identify trends and fundamental changes in respiratory mechanics. CONCLUSION: Overall, this is a proof of concept study that shows the potential of continuous monitoring of respiratory mechanics in clinical practice. Respiratory system mechanics vary with disease state development and in response to MV settings. Therefore, titrating PEEP to minimal elastance theoretically results in optimal PEEP selection. Trends matched clinical expectation demonstrating robustness and potential for guiding MV therapy. However, further research is required to confirm the use of such real-time methods in actual ARDS patients, both sedated and spontaneously breathing.
Disciplines :
General & internal medicine
Author, co-author :
Van Drunen, EJ
Chiew, YS
Chase, JG
Shaw, GM
LAMBERMONT, Bernard  ;  Centre Hospitalier Universitaire de Liège - CHU > Frais communs médecine
JANSSEN, Nathalie ;  Centre Hospitalier Universitaire de Liège - CHU > Urgences
Damanhuri, NS
Desaive, Thomas  ;  Université de Liège - ULiège > Département d'astrophys., géophysique et océanographie (AGO) > Thermodynamique des phénomènes irréversibles
Language :
English
Title :
Expiratory model-based method to monitor ARDS disease state
Publication date :
26 June 2013
Journal title :
BioMedical Engineering OnLine
eISSN :
1475-925X
Publisher :
BioMed Central, London, United Kingdom
Volume :
12
Issue :
57
Peer reviewed :
Peer Reviewed verified by ORBi
Available on ORBi :
since 15 January 2014

Statistics


Number of views
54 (16 by ULiège)
Number of downloads
121 (3 by ULiège)

Scopus citations®
 
42
Scopus citations®
without self-citations
9
OpenCitations
 
36

Bibliography


Similar publications



Contact ORBi