Article (Scientific journals)
Effects of Neurally Adjusted Ventilatory Assist (NAVA) levels in non-invasive ventilated patients: titrating NAVA levels with electric diaphragmatic activity and tidal volume matching
Chiew, YS; Chase, JG; LAMBERMONT, Bernard et al.
2013In BioMedical Engineering OnLine, 12 (61)
Peer Reviewed verified by ORBi
 

Files


Full Text
Chiew YS et al. Biomed Eng Online. 2013.pdf
Publisher postprint (1.17 MB)
Download

All documents in ORBi are protected by a user license.

Send to



Details



Keywords :
Mechanical ventilation; NAVA; Non-invasive ventilation; Patient-ventilator interaction; Matching
Abstract :
[en] BACKGROUND: Neurally adjusted ventilatory assist (NAVA) delivers pressure in proportion to diaphragm electrical activity (Eadi). However, each patient responds differently to NAVA levels. This study aims to examine the matching between tidal volume (Vt) and patients' inspiratory demand (Eadi), and to investigate patient-specific response to various NAVA levels in non-invasively ventilated patients. METHODS: 12 patients were ventilated non-invasively with NAVA using three different NAVA levels. NAVA100 was set according to the manufacturer's recommendation to have similar peak airway pressure as during pressure support. NAVA level was then adjusted ±50% (NAVA50, NAVA150). Airway pressure, flow and Eadi were recorded for 15 minutes at each NAVA level. The matching of Vt and integral of Eadi (ʃEadi) were assessed at the different NAVA levels. A metric, Range90, was defined as the 5-95% range of Vt/ʃEadi ratio to assess matching for each NAVA level. Smaller Range90 values indicated better matching of supply to demand. RESULTS: Patients ventilated at NAVA50 had the lowest Range90 with median 25.6 uVs/ml [Interquartile range (IQR): 15.4-70.4], suggesting that, globally, NAVA50 provided better matching between ʃEadi and Vt than NAVA100 and NAVA150. However, on a per-patient basis, 4 patients had the lowest Range90 values in NAVA100, 1 patient at NAVA150 and 7 patients at NAVA50. Robust coefficient of variation for ʃEadi and Vt were not different between NAVA levels. CONCLUSIONS: The patient-specific matching between ʃEadi and Vt was variable, indicating that to obtain the best possible matching, NAVA level setting should be patient specific. The Range90 concept presented to evaluate Vt/ʃEadi is a physiologic metric that could help in individual titration of NAVA level.
Disciplines :
General & internal medicine
Author, co-author :
Chiew, YS
Chase, JG
LAMBERMONT, Bernard  ;  Centre Hospitalier Universitaire de Liège - CHU > Frais communs médecine
Roeseler, J
Pretty, C
Bialais, E
Sottiaux, T
Desaive, Thomas  ;  Université de Liège - ULiège > Département d'astrophys., géophysique et océanographie (AGO) > Thermodynamique des phénomènes irréversibles
Language :
English
Title :
Effects of Neurally Adjusted Ventilatory Assist (NAVA) levels in non-invasive ventilated patients: titrating NAVA levels with electric diaphragmatic activity and tidal volume matching
Publication date :
02 July 2013
Journal title :
BioMedical Engineering OnLine
eISSN :
1475-925X
Publisher :
BioMed Central, London, United Kingdom
Volume :
12
Issue :
61
Peer reviewed :
Peer Reviewed verified by ORBi
Available on ORBi :
since 14 January 2014

Statistics


Number of views
73 (17 by ULiège)
Number of downloads
126 (5 by ULiège)

Scopus citations®
 
9
Scopus citations®
without self-citations
2
OpenCitations
 
9

Bibliography


Similar publications



Contact ORBi