Abstract :
[en] A hydraulic design equation for Piano Key Weirs is set up using the results of a large experimental parametric study. Comparison of the analytical formulation with experi-mental data from various physical modeling studies, considering idealized as well as real projects Piano Key Weirs configurations, shows a 15% accuracy in unit discharge prediction on a large range of geometric parameters values. Comparison of the proposed formulation to two other recently proposed equations highlights the importance to consider such analytical approaches inside the range of parameter values for which they have been validated.
Scopus citations®
without self-citations