Article (Scientific journals)
Myocardial infarct size quantification in mice by SPECT using a novel algorithm independent of a normal perfusion database
Roelants, Véronique; DELGAUDINE, Marie; Walrand, Stephan et al.
2012In EJNMMI Research, 2, p. 64-75
Peer Reviewed verified by ORBi
 

Files


Full Text
293.pdf
Publisher postprint (3.48 MB)
Download

All documents in ORBi are protected by a user license.

Send to



Details



Keywords :
infarct size; quantification; mouse; SPECT
Abstract :
[en] Background: There is a growing interest in developing non-invasive imaging techniques permitting infarct size (IS) measurements in mice. The aim of this study was to validate the high-resolution rodent Linoview single photon emission computed tomography (SPECT) system for non-invasive measurements of IS in mice by using a novel algorithm independent of a normal database, in comparison with histology. Methods: Eleven mice underwent a left coronary artery ligature. Seven days later, animals were imaged on the SPECT 2h30 after injection of 173 ± 27 MBq of Tc-99m-sestamibi. Mice were subsequently killed, and their hearts were excised for IS determination with triphenyltetrazolium chloride (TTC) staining. SPECT images were reconstructed using the expectation maximization maximum likelihood algorithm, and the IS was calculated using a novel algorithm applied on the 20-segment polar map provided by the commercially available QPS software (Cedars-Sinai Medical Center, CA, USA). This original method is attractive by the fact that it does not require the implementation of a normal perfusion database. Results: Reconstructed images allowed a clear delineation of the left ventricles borders in all mice. No significant difference was found between mean IS determined by SPECT and by TTC staining [37.9 ± 17.5% vs 35.6 ± 17.2%, respectively (P = 0.10)]. Linear regression analysis showed an excellent correlation between IS measured on the SPECT images and IS obtained with TTC staining (y = 0.95x + 0.03 (r = 0.97; P < 0.0001)), without bias, as demonstrated by the Bland-Altman plot. Conclusion: Our results demonstrate the accuracy of the method for the measurement of myocardial IS in mice with the Linoview SPECT system.
Disciplines :
Hematology
Author, co-author :
Roelants, Véronique
DELGAUDINE, Marie ;  Centre Hospitalier Universitaire de Liège - CHU > Département Physique Médicale
Walrand, Stephan
Lhommel, Renaud
Beguin, Yves  ;  Université de Liège - ULiège > GIGA-R : Hématologie
Jamar, François
Vanoverschelde, Jean-Louis
Language :
English
Title :
Myocardial infarct size quantification in mice by SPECT using a novel algorithm independent of a normal perfusion database
Publication date :
2012
Journal title :
EJNMMI Research
eISSN :
2191-219X
Publisher :
Springer, Heidelberg, Germany
Volume :
2
Pages :
64-75
Peer reviewed :
Peer Reviewed verified by ORBi
Available on ORBi :
since 11 July 2013

Statistics


Number of views
54 (1 by ULiège)
Number of downloads
157 (0 by ULiège)

Scopus citations®
 
3
Scopus citations®
without self-citations
3
OpenCitations
 
2

Bibliography


Similar publications



Contact ORBi