[en] AIMS: Off-line post-processing of colour tissue Doppler from digital loops may allow objective quantification of dobutamine stress echocardiography. We assessed the reproducibility of off-line measurements of regional myocardial velocities. METHODS AND RESULTS: Nine observers analysed 10 studies, each making 2400 observations. Coefficients of variation in basal segments from apical windows, at rest and maximal stress, were 9-14% and 11-18% for peak systolic velocity, 16-18% and 17-19% for time-to-peak systolic velocity, 9-17% and 18-24% for systolic velocity time integral, and 18-23% and 21-27% for systolic acceleration. Coefficients of variation for diastolic velocities in basal segments at rest were 11-40%. Coefficients of variation for peak systolic velocity were 10-24% at rest and 14-28% at peak in mid segments, and 19-53% and 29-69% in apical segments. From parasternal windows coefficients of variation for peak systolic velocity were 14-16% in basal posterior, and 19-29% in mid-anterior segments. High variability makes measurement unreliable in apical and basal anterior septal segments. The feasibility of obtaining traces was tested in 92 subjects, and >90% in all basal and mid segments apart from the anterior septum. CONCLUSION: Quantification of myocardial functional reserve by off-line analysis of colour tissue Doppler acquired during dobutamine stress is feasible and reproducible in 11 segments of the left ventricle. The most reliable measurements are systolic velocities of longitudinal motion in basal segments.
Gianrossi R, Detrano R, Mulvihill D et al. Exercise-induced ST depression in the diagnosis of coronary artery disease. A meta-analysis. Circulation 1989; 80: 87-98.
Okin PM, Kligfield P. Gender-specific criteria and performance of the exercise electrocardiogram. Circulation 1995; 92: 1209-1216.
Picano E, Lattanzi F, Orlandini A, Marini C, L'Abbate A. Stress echocardiography and the human factor: the importance of being expert. J Am Coll Cardiol 1991; 17: 666-669.
Hoffmann R, Lethen H, Marwick T et al. Analysis of interinstitutional observer agreement in interpretation of dobutamine stress echocardiograms. J Am Coll Cardiol 1996; 27: 330-336.
Wilkenshoff UM, Sovany A, Wigstrom L, et al. Regional mean systolic myocardial velocity estimation by real-time color Doppler myocardial imaging: a new technique for quantifying regional systolic function. J Am Soc Echocardiogr 1998; 11: 683-692.
Schiller NB, Shah PM, Crawford M et al. Recommendations for quantitation of the left ventricle by two- dimensional echocardiography. American Society of Echocardiography Committee on Standards, Subcommittee on Quantitation of Two-Dimensional Echocardiograms. J Am Soc Echocardiogr 1989; 2: 358-367.
Takeuchi M, Sonoda S, Miura Y, Kuroiwa A. Reproducibility of dobutamine digital stress echocardiography. J Am Soc Echocardiogr 1997; 10: 344-351.
Derumeaux G, Ovize M, Loufoua J et al. Doppler tissue imaging quantitates regional wall motion during myocardial ischemia and reperfusion. Circulation 1998; 97: 1970 1977.
Vatner SF. Correlation between acute reductions in myocardial blood flow and function in conscious dogs. Circ Res 1980; 47: 201-207.
Brodin LA, van der Linden J, Olstad B. Echocardiographic functional images based on tissue velocity information. Herz 1998; 23: 491-498.
Vinereanu D, Khokhar A, Fraser AG. Reproducibility of pulsed wave tissue Doppler echocardiography. J Am Soc Echocardiogr 1999; 12: 492-499.
Cain P, Marwick TH, Case C et al. Assessment of regional long-axis function during dobutamine echocardiography. Clin Sci (Colch.) 2001; 100: 423-432.
Cain P, Baglin T, Case C, Spicer D, Short L, Marwick TH. Application of tissue Doppler to interpretation of dobutamine echocardiography and comparison with quantitative coronary angiography. Am J Cardiol 2001; 87: 525-531.
Katz WE, Gulati VK, Mahler CM, Gorcsan J, III. Quantitative evaluation of the segmental left ventricular response to dobutamine stress by tissue Doppler echocardiography. Am J Cardiol 1997; 79: 1036-1042.
Palka P, Lange A, Fleming AD et al. Differences in myocardial velocity gradient measured throughout the cardiac cycle in patients with hypertrophic cardiomyopathy, athletes and patients with left ventricular hypertrophy due to hypertension. J Am Coll Cardiol 1997; 30: 760-768.
Hoffmann R, Marwick TH, Poldermans D et al. Refinements in stress echocardiographic techniques improve interinstitutional agreement in interpretation of dobutamine stress echocardiograms. Eur Heart J 2002; 23: 821-829.