No full text
Article (Scientific journals)
Measurement of insulin sensitivity by the minimal model method using a simplified intravenous glucose tolerance test: validity and reproducibility.
Duysinx, Bernard; Scheen, André; Gerard, Pascale et al.
1994In Diabète et Métabolisme, 20 (4), p. 425-32
Peer Reviewed verified by ORBi
 

Files


Full Text
No document available.

Send to



Details



Keywords :
Adult; Female; Glucose Tolerance Test/methods; Humans; Insulin Resistance; Male; Middle Aged; Models, Biological; Reference Values; Reproducibility of Results; Specimen Handling/methods; Tolbutamide/pharmacology
Abstract :
[en] This study aimed at testing whether 12 rather than 26 plasma glucose and insulin determinations can be used to calculate the indices of insulin sensitivity and of glucose effectiveness using Bergman's minimal model during a simple intravenous glucose tolerance test performed without tolbutamide injection. Two intravenous glucose tolerance tests (separated by 1 week) were performed in 7 lean normal subjects and a single test was performed in 9 severely obese non-diabetic subjects. Intra-subject reproducibility of insulin sensitivity was not significantly different when 26 or 12 time-points were analyzed (CV = 16.8 +/- 3.4 versus 18.9 +/- 3.8% respectively). Compared with the insulin sensitivity of the lean subjects, that of obese subjects was significantly (P < 0.001) and similarly reduced when using 12 (2.14 +/- 0.34 versus 7.97 +/- 1.29 10(-4)min-1/mU.1-1) rather than 26 determinations (2.13 +/- 0.42 versus 6.95 +/- 1.12 10(-4) min-1/mU.1-1) respectively. Glucose effectiveness was less reproducible than insulin sensitivity and was slightly diminished by the reduction of blood samples (relative error: -9.7 +/- 4.4%; P < 0.05). Finally, glucose effectiveness tended to be slightly lower in the morbidly obese subjects than in the lean controls with both modes of calculation. In conclusion, in non-diabetic subjects, the insulin sensitivity index can be accurately measured during a simple intravenous glucose tolerance test, without tolbutamide injection and with only 12 blood samples. The possibility of performing a simplified test should contribute to increase the use of the minimal model method for estimating insulin sensitivity in clinical practice.
Disciplines :
Endocrinology, metabolism & nutrition
Author, co-author :
Duysinx, Bernard ;  Centre Hospitalier Universitaire de Liège - CHU > Pneumologie-Allergologie
Scheen, André  ;  Université de Liège - ULiège > Département des sciences cliniques > Diabétologie, nutrition et maladie métaboliques - Médecine interne générale
Gerard, Pascale ;  Centre Hospitalier Universitaire de Liège - CHU > Neurologie CHR
Letiexhe, Michel ;  Centre Hospitalier Universitaire de Liège - CHU > Diabétologie,nutrition, maladies métaboliques
Paquot, Nicolas ;  Centre Hospitalier Universitaire de Liège - CHU > Diabétologie,nutrition, maladies métaboliques
Lefebvre, Pierre ;  Centre Hospitalier Universitaire de Liège - CHU > Diabétologie,nutrition, maladies métaboliques
Language :
English
Title :
Measurement of insulin sensitivity by the minimal model method using a simplified intravenous glucose tolerance test: validity and reproducibility.
Publication date :
1994
Journal title :
Diabète et Métabolisme
ISSN :
0338-1684
Publisher :
Masson, Paris, France
Volume :
20
Issue :
4
Pages :
425-32
Peer reviewed :
Peer Reviewed verified by ORBi
Available on ORBi :
since 05 June 2009

Statistics


Number of views
101 (4 by ULiège)
Number of downloads
0 (0 by ULiège)

Scopus citations®
 
21
Scopus citations®
without self-citations
15

Bibliography


Similar publications



Contact ORBi