Krueger G, Glover GH, (2001) Physiological noise in oxygenation-sensitive magnetic resonance imaging. Magn Reson Med 46 (4): 631-637.
Triantafyllou C, Hoge RD, Krueger G, Wiggins CJ, Potthast A, et al. (2005) Comparison of physiological noise at 1.5 T, 3 T and 7 T and optimization of fMRI acquisition parameters. Neuroimage 26 (1): 243-250.
Triantafyllou C, Polimeni JR, Wald LL, (2011) Physiological noise and signal-to-noise ratio in fMRI with multi-channel array coils. Neuroimage 55 (2): 597-606.
Hutton C, Josephs O, Stadler J, Featherstone E, Reid A, et al. (2011) The impact of physiological noise correction on fMRI at 7 T. Neuroimage 57. (1): 101-112.
Kellman P, McVeigh ER, (2005) Image reconstruction in SNR units: a general method for SNR measurement. Magn Reson Med 54 (6): 1439-1447.
Roemer PB, Edelstein WA, Hayes CE, Souza SP, Mueller OM, (1990) The NMR phased array. Magn Reson Med 16 (2): 192-225.
Griswold MA, Jakob PM, Heidemann RM, Nittka M, Jellus V, et al. (2002) Generalized autocalibrating partially parallel acquisitions (GRAPPA). Magn Reson Med 47 (6): 1202-1210.
Constantinides CD, Atalar E, McVeigh ER, (1997) Signal-to-noise measurements in magnitude images from NMR phased arrays. Magn Reson Med 38 (5): 852-857.
Wiggins GC, Triantafyllou C, Potthast A, Reykowski A, Nittka M, et al. (2006) 32-channel 3 Tesla receive-only phased-array head coil with soccer-ball element geometry. Magn Reson Med 56 (1): 216-223.
Dietrich O, Raya JG, Reeder SB, Reiser MF, Schoenberg SO, (2007) Measurement of signal-to-noise ratios in MR images: influence of multichannel coils, parallel imaging, and reconstruction filters. J Magn Reson Imaging 26 (2): 375-385.
Gilbert G, (2007) Measurement of signal-to-noise ratios in sum-of-squares MR images. J Magn Reson Imaging 26 (6): 1678.
Koay CG, Basser PJ, (2006) Analytically exact correction scheme for signal extraction from noisy magnitude MR signals. J Magn Reson 179 (2): 317-322.
Redpath TW, (1992) Noise correlation in multicoil receiver systems. Magn Reson Med 24 (1): 85-89.
Hayes CE, Roemer PB, (1990) Noise correlations in data simultaneously acquired from multiple surface coil arrays. Magn Reson Med 16 (2): 181-191.
Edelstein WA, Glover GH, Hardy CJ, Redington RW, (1986) The intrinsic signal-to-noise ratio in NMR imaging. Magn Reson Med 3 (4): 604-618.
Friedman L, Glover GH, (2006) Report on a multicenter fMRI quality assurance protocol. J Magn Reson Imaging 23 (6): 827-839.
Greve DN, Mueller BA, Liu T, Turner JA, Voyvodic J, et al. (2011) A novel method for quantifying scanner instability in fMRI. Magn Reson Med 65 (4): 1053-1061.
Weiskopf N, Hutton C, Josephs O, Deichmann R, (2006) Optimal EPI parameters for reduction of susceptibility-induced BOLD sensitivity losses: a whole-brain analysis at 3 T and 1.5 T. Neuroimage 33. (2): 493-504.
Josephs O, Deichmann R, Turner R (2008) Trajectory measurement and generalised reconstruction in rectilinear EPI. In: Proceedings of ISMRM 8, Denver, Colorado, USA.
Wright PJ, Mougin OE, Totman JJ, Peters AM, Brookes MJ, et al. (2008) Water proton T1 measurements in brain tissue at 7, 3, and 1.5 T using IR-EPI, IR-TSE, and MPRAGE: results and optimization. MAGMA 21 (1-2): 121-130.
Lutti A, Hutton C, Stadler J, Josephs O, Speck O et al. (2010) Radio frequency (B1) field mapping at 7T using 3D SE/STE EPI technique. In: Proceedings of Joint Annual Meeting ISMRM-ESMRM, Stockholm, Sweden.
Friston K. Statistical Parametric Mapping: The Analysis of Functional Brain Images. (2007) In:Friston K, Ashburner J, Kiebel S, Nichols T, Penny W, editors. Statistical Parametric Mapping. London: Elsevier Ltd. 10-31.
Hutton C, Bork A, Josephs O, Deichmann R, Ashburner J, et al. (2002) Image distortion correction in fMRI: A quantitative evaluation. Neuroimage 16 (1): 217-240.
Tzourio-Mazoyer N, Landeau B, Papathanassiou D, Crivello F, Etard O, et al. (2002) Automated anatomical labeling of activations in SPM using a macroscopic anatomical parcellation of the MNI MRI single-subject brain. Neuroimage 15 (1): 273-289.
Evans A, Collins DL, Mills SR, Brown ED, Kelly RL, et al. (1993) 3D statistical neuroanatomical models from 305 MRI volumes [abstract]. In: Anonymous. 1813-1817.
Bodurka J, Ye F, Petridou N, Murphy K, Bandettini PA, (2007) Mapping the MRI voxel volume in which thermal noise matches physiological noise-implications for fMRI. Neuroimage 34 (2): 542-549.
Gonzalez-Castillo J, Roopchansingh V, Bandettini PA, Bodurka J, (2011) Physiological noise effects on the flip angle selection in BOLD fMRI. Neuroimage 54 (4): 2764-2778.