Article (Scientific journals)
Reproducibility of measurements of potential doubling time of tumor cells in the multicenter NCI protocol T92-0045
Wilson, G-D; Paschoud, N; Pavy, J-J et al.
1999In British Journal of Cancer, 79 (2), p. 323-332
Peer Reviewed verified by ORBi
 

Files


Full Text
reproducibility of measurements of potential doubling time of tumor cells in the multicenter vol 79 (2) 1999.pdf
Author postprint (116.94 kB)
Download

All documents in ORBi are protected by a user license.

Send to



Details



Keywords :
proliferation; reproducibility; conventional radiotherapy; multicentre; flow cytometry
Abstract :
[en] Summary We compared the flow cytometric measurement and analysis of the potential doubling time ( Tpot) between three centres involved in the National Cancer Institute (NCI) protocol T92-0045. The primary purpose was to understand and minimize the variation within the measurement. A total of 102 specimens were selected at random from patients entered into the trial. Samples were prepared, stained, run and analysed in each centre and a single set of data analysed by all three centres. Analysis of the disc data set revealed that the measurement of labelling index (LI) was robust and reproducible. The estimation of duration of S-phase ( Ts) was subject to errors of profile interpretation, particularly DNA ploidy status, and analysis. The LI dominated the variation in Tpot such that the level of final agreement, after removal of outliers and ploidy agreement, reached correlation coefficients of 0.9. The sample data showed poor agreement within each of the components of the measurement. There was some improvement when ploidy was in agreement, but correlation coefficients failed to exceed values of 0.5 for Tpot. The data suggest that observer-associated analysis of Ts and tissue processing and tumour heterogeneity were the major causes of variability in the Tpot measurement. The first two aspects can be standardized and minimized, but heterogeneity will remain a problem with biopsy techniques.
Disciplines :
Hematology
Oncology
Author, co-author :
Wilson, G-D;  Mount Vernon Hospital > Gray Laboratory Cancer Research Trust > Northwood,Middlesex HA6 2JR, UK
Paschoud, N;  Clinique La Source > Laboratoire de Cytométrie en Flux > Lausanne, Switzerland
Pavy, J-J;  Centre Hospitalier Universitaire > Radiotherapy > Besançon, France
Weber, K.;  Clinique La Source > Laboratoire de Cytométrie en Flux > Lausanne, Switzerland
Weber, P.;  Clinique La Source > Laboratoire de Cytométrie en Flux > Lausanne, Switzerland
Dubray, B;  Centre Hospitalier Universitaire Vaudois > Radiotherapy > Lausanne, Switzerland
COUCKE, Philippe  ;  Centre Hospitalier Universitaire Vaudois
Language :
English
Title :
Reproducibility of measurements of potential doubling time of tumor cells in the multicenter NCI protocol T92-0045
Publication date :
1999
Journal title :
British Journal of Cancer
ISSN :
0007-0920
eISSN :
1532-1827
Publisher :
Nature Publishing Group, London, United Kingdom
Volume :
79
Issue :
2
Pages :
323-332
Peer reviewed :
Peer Reviewed verified by ORBi
Available on ORBi :
since 15 July 2009

Statistics


Number of views
90 (4 by ULiège)
Number of downloads
84 (1 by ULiège)

Scopus citations®
 
11
Scopus citations®
without self-citations
6
OpenCitations
 
15

Bibliography


Similar publications



Contact ORBi