Article (Scientific journals)
Long-Term Performance in Vitro and in Vivo of Dual-Energy X-Ray Absorptiometry
Reginster, Jean-Yves; Deroisy, Rita; Zegels, Brigitte et al.
1995In Clinical Rheumatology, 14 (2), p. 180-6
Peer Reviewed verified by ORBi
 

Files


Full Text
Long term performance in vitro and in vivo of dual energy X ray absorptiometry.pdf
Publisher postprint (581.46 kB)
Request a copy

All documents in ORBi are protected by a user license.

Send to



Details



Abstract :
[en] Dual-energy X-ray absorptiometry (DXA) is actually considered as one of the most appropriate techniques for measuring bone mineral content (BMC) and bone mineral density (BMD). An anthropomorphic phantom and a 25-year-old girl were repeatedly measured, 160 times and 50 times respectively, over an 18-month period to investigate performance in vitro and in vivo of a commercial DXA equipment (HOLOGIC QDR 1000). DXA is a highly accurate technique, the BMC and BMD determinations only overestimated the exact value of the phantom by 0.20% and 0.51% respectively. In vivo long-term (18 months) reproducibility of BMD of the spine is characterized by an interassay coefficient of variation (CVt) of 0.8% while, for the different regions of interest of the hip, BMD CVt varies from 1.1% (total zone) to 5.3% (Ward's triangle). In the subject tested, BMD sensitivity for changes of 2.2% at the lumbar spine and 3% at the hip were recorded.
Disciplines :
Rheumatology
Author, co-author :
Reginster, Jean-Yves  ;  Université de Liège - ULiège > Département des sciences de la santé publique > Epidémiologie et santé publique
Deroisy, Rita  ;  Centre Hospitalier Universitaire de Liège - CHU > Médecine de l'appareil locomoteur
Zegels, Brigitte ;  Université de Liège - ULiège > Département des sciences de la santé publique > Epidémiologie et santé publique
Jupsin, Isabelle ;  Centre Hospitalier Universitaire de Liège - CHU > Médecine de l'appareil locomoteur
Albert, Adelin  ;  Université de Liège - ULiège > Département des sciences de la santé publique > Informatique médicale et biostatistique
Franchimont, P.
Language :
English
Title :
Long-Term Performance in Vitro and in Vivo of Dual-Energy X-Ray Absorptiometry
Publication date :
March 1995
Journal title :
Clinical Rheumatology
ISSN :
0770-3198
eISSN :
1434-9949
Publisher :
Springer, Germany
Volume :
14
Issue :
2
Pages :
180-6
Peer reviewed :
Peer Reviewed verified by ORBi
Available on ORBi :
since 02 May 2012

Statistics


Number of views
65 (4 by ULiège)
Number of downloads
1 (0 by ULiège)

Scopus citations®
 
10
Scopus citations®
without self-citations
7
OpenCitations
 
9
OpenAlex citations
 
11

Bibliography


Similar publications



Contact ORBi