[en] Ultrasonography of the left and right femoral artery and vein was performed in 5 conscious horses. Velocity waveforms, recorded using low pulse repetition frequency, were used to calculate time-averaged mean velocity (TAV), velocity of component a (TaVa), velocity of component b (TaVb) and volumetric flow. Waveform analysis included calculation of early diastolic deceleration slope (EDDS) and pulsatility index (PI) and subjective description of the waveform. Measurements were recorded at monthly intervals for 6 months. The repeated measurements were used to determine the within-horse variation. Horses were then anaesthetised with halothane and the same measurements recorded 60 min after induction. Differences between measurements recorded in conscious and anaesthetised horses were determined. Within-horse variability for diameters of femoral arteries and veins was small (CV<10%). Within variability for all other measurements was marked (CV>11%), with within-horse variability being the largest for femoral venous flow (CV>35%). Source of variability was measurement error and biological variation. Despite variability in conscious horses it was possible to detect changes in blood flow during anaesthesia. In the femoral arteries, volumetric flow was lower and EDDS and PI was higher in anaesthetised horses. In the femoral veins, volumetric flow was also lower in anaesthetised horses. Therefore Doppler ultrasound appears to be a useful technique for studying blood flow in conscious and anaesthetised horses
Disciplines :
Veterinary medicine & animal health Anatomy (cytology, histology, embryology...) & physiology
Author, co-author :
Raisis, Anthea L; The Centre for Equine Studies, The Animal Health Trust, PO Box 5, Newmarket, Suffolk CB8 8JH, UK
Young, L. E.; The Centre for Equine Studies, The Animal Health Trust, PO Box 5, Newmarket, Suffolk CB8 8JH, UK
Meire, H. B.; Department of Radiology, Kings College Hospital, Denmark Hill, London SE5 9RS, UK
Taylor, Polly M; Department of Clinical Veterinary Medicine, University of Cambridge, Madingly Road, Cambridge CB3 0ES, UK
Walsh, K.; The Centre for Equine Studies, The Animal Health Trust, PO Box 5, Newmarket, Suffolk CB8 8JH, UK
Lekeux, Pierre ; Université de Liège - ULiège > Département de sciences fonctionnelles > Physiologie - Doyen de la Faculté de Médecine vétérinaire
Language :
English
Title :
Variability of Doppler ultrasound measurements of hindlimb blood flow in conscious horses
Publication date :
2000
Journal title :
Equine Veterinary Journal
ISSN :
0425-1644
eISSN :
2042-3306
Publisher :
Equine Veterinary Journal Ltd, Newmarket Suffolk, United Kingdom
Almond, N.E. (1994) Laser Doppler Flowmetry: theory and practice. In: Laser Doppler, Eds: G. Belcaro, U. Hoffman, A. Bollinger and A. Nicolaides, Med-Orion, London. pp 17-31.
Bland, J.M. (1995) Clinical measurement. In: An Introduction to Medical Statistics, Oxford University Press. New York. pp 265-290.
Borgos, J. (1994) Principles of instrumentation: Calibration and technical issues. In: Laser Doppler, Eds: G. Belcaro, U. Hoffman, A. Bollinger and A. Nicolaides, Med-Orion, London. pp 3-16.
Duazat, M.M.J., Laroche, J-P., Lopez, F-M., Janbon, C. and Woodcock, J.P. (1993) Vascular ultrasound-limbs. In: Abdominal and General Ultrasound, Eds: D. Cosgrove, H. Meire and K. Dewbury, Churchill Livingston, London. pp 357-882.
Eik-Nes, S.H., Marsal, K. and Kristoffersen, K. (1984) Methodology and basic problems related to blood flow studies in human fetus. Ultrasound Med. Biol. 10, 329-337.
Evans, D.H., McDicken, W.N., Skidmore, R. and Woodcock, J.P. (1989) Doppler Ultrasound: Physics, Instrumentation and Clinical Application. John Wiley and Sons, New York. pp 115-205.
Fleiss, J.L. (1986) The Design and Analysis of Clinical Experiments. John Wiley and Sons, New York. pp 1-32.
Gill, R.W. (1985) Measurement of blood flow by ultrasound: accuracy and sources of error. Ultrasound med. Biol. 11, 625-641.
Gudmundsson, S., Fairlie, P., Lingman, G. and Marsal, K. (1990) Recording of blood flow velocity waveforms in the uteroplacental and umbilical circulation: reproducibility study and comparison of pulsed and continuous wave Doppler ultrasound. J. clin. Ultrasound 18, 97-101.
Hennig, G.E. (1995) The effect of xylazine on equine muscle surface capillary blood flow. J. vet. Pharmacol. Therap. 18, 388-390.
Hoffman, K.L., Griffiths, I. and Wood, A.K.W. (1995) Arterial haemodynamics in equine foot, Proceedings of the Australasian Society of Ultrasound in Medicine 25, A49-50.
LeJemtel, T.H., Katz, S., Jondeau, G. and Soloman, S. (1992) Critical analysis of methods for assessing regional blood flow and their reliability in clinical medicine. Chest 101, s219-s222.
Levy, B.I., Vallachares, M.R., Ghaem, A. and Martinaud, J.P. (1979) Comparison of plethysmographic methods with pulsed Doppler flowmetry. Am. J. Physiol. 236, H899-H903.
Lewis, P., Psaila, J.V., Davies, W.T., McCarty, K. and Woodcock, J.P. (1986) Measurement of volume flow in the human common femoral artery using duplex a ultrasound system. Ultrasound Med. Biol. 12, 777-784.
Meire, H.B. (1993) Doppler. In: Abdominal and General Ultrasound. Eds: D. Cosgrove, H. Meire and K. Dewbury, Churchill Livingston, Edinburgh. pp 67-95.
Nomura, K., Seto, H., Kamisaki, Y., Kageyama, M. Nagayoshi, T. and Kakishita, M. (1996) Doppler spectral analysis of blood flow velocities in common femoral artery: age-related changes in healthy subjects and characteristics of abnormal haemodynamics in obstructive arterial disease. Radiation Medicine. 14, 13-17.
Norman, W.M., Court, M.H., Dodman, N.H. and Pipers, F.S. (1992) Muscle surface capillary blood flow in three anaesthetised horses using laser Doppler flowmetry-preliminary results (abstract). Vet Surg. 21, 169.
Pinheiro, L., Jain, S., Cooper, J.W. and Nanda, N.C. (1993) Conventional and colour doppler evaluation of lower extremity vessels. In: Doppler Echocardiography. Ed: R. K. Bussy, Lea & Febiger, Pennsylvania, pp 365-379.
Polak, J.F. (1992) Doppler sonography: an overview. In: Peripheral Vascular Sonography. A Practical Guide. Ed: T.H. Grayson. Williams & Wilkins, Baltimore, pp 1-47.
Raisis, A.L., Young. L.E., Meire, H., Walsh, K., Taylor, P.M. and Lekeux, P. (2000) Repeatability of Doppler Ultrasound measurements of hindlimb blood flow in anaesthetised horses. Equine vet. J. (In Press)
Serteyn, D., Mottart, E., Michaux, C., Micheels, L., Philippart, C., Lavergne, L., Guillon, C. and Lamy, M. (1986) Laser Doppler Flowmetry: Muscular microcirculation in anaesthetised horses. Equine vet. J. 18, 391-395.
Steffey, E.P, and Rowland, D. (1978) Cardiovascular effects of halothane in the horse. Am. J. vet. Res. 39, 611-615.
Taylor, P.M. and Young, S.S. (1990) The effect of limb position on venous and compartmental pressure in the forelimb of ponies. J. Ass. vet. Anaesth. 17, 35-37.
Teague, M.J., Willson, K., Battye, C.K., Taylor, M.G., Griffin, D.R., Campbell, S. and Roberts, V.C. (1985) A combined ultrasonic linear array scanner and pulsed Doppler velocimeter for the estimation of blood flow in the foetus and adult abdomen-I; technical aspects. Ultrasound Med. Biol. 11, 27-36.
Walker, M.A.G.D. (1986) Effects of acetylpromazine on the haemodynamics of the equine metatarsal artery, as determined by two-dimensional real-time and pulsed Doppler ultrasonography. Am. J. vet. Res. 47, 1075-1078.
Weaver, B.M.Q., Lunn, C.E.M. and Staddon, G.E. (1984) Muscle perfusion in the horse. Equine vet. J. 16, 66-68.
Weyman, A.E. (1994) Principles of Doppler flow measurement. In: Principles and Practice of Echocardiography 2nd edn., Lea & Febiger. Pennsylvania, pp 143-162.
Zierler, R.E. and Zierler, B.K. (1992) Duplex sonography of lower extremity arteries. In: Introduction to Vascular Ultrasonography, Ed: W.J. Zweibel, W.B. Saunders Co., Philadelphia, pp 237-251.
Zierler, B.K., Kirkman, T.R., Kraiss, L.W., Reiss, W.G., Horn, J.R., Bauer, L.A., Clowes, A.W. and Kohler, T.R. (1992) Accuracy of duplex scanning for measurement of arterial flow. J. vasc. Surg. 16, 520-526.