Profil

Guérard Suzanne

See author's contact details
Main Referenced Co-authors
Lilien, Jean-Louis  (9)
Destiné, Jacques  (4)
Godard, Bertrand  (3)
Cloet, Eric (1)
Feiereisen, Jean-Marc (1)
Main Referenced Keywords
monitoring (4); power lines (4); aeolian vibration (2); aeolian vibrations (2); fatigue (2);
Main Referenced Disciplines
Energy (6)
Electrical & electronics engineering (4)
Mechanical engineering (2)
Materials science & engineering (1)

Publications (total 11)

The most downloaded
1287 downloads
Guérard, S. (2011). Power Line Conductors, a Contribution to the Analysis of their Dynamic Behaviour [Doctoral thesis, ULiège - Université de Liège]. ORBi-University of Liège. https://orbi.uliege.be/handle/2268/103387 https://hdl.handle.net/2268/103387

The most cited

16 citations (Scopus®)

Godard, B., Guérard, S., & Lilien, J.-L. (October 2011). Original real-time observations of aeolian vibrations on power-line conductors. IEEE Transactions on Power Delivery, 26 (4), 2111-2117. doi:10.1109/TPWRD.2011.2158859 https://hdl.handle.net/2268/102095

Guérard, S. (2011). Power Line Conductors, a Contribution to the Analysis of their Dynamic Behaviour [Doctoral thesis, ULiège - Université de Liège]. ORBi-University of Liège. https://orbi.uliege.be/handle/2268/103387

Guérard, S., & Lilien, J.-L. (2011). Power Line conductors self damping : a new approach. In Proceedings of the 9th International Symposium on Cable Dynamics (pp. 335-443).
Peer reviewed

Guérard, S., Godard, B., & Lilien, J.-L. (October 2011). Aeolian vibration on power-line conductors, evaluation of actual self damping. IEEE Transactions on Power Delivery, 26 (4), 2118-2122. doi:10.1109/TPWRD.2011.2151211
Peer Reviewed verified by ORBi

Godard, B., Guérard, S., & Lilien, J.-L. (October 2011). Original real-time observations of aeolian vibrations on power-line conductors. IEEE Transactions on Power Delivery, 26 (4), 2111-2117. doi:10.1109/TPWRD.2011.2158859
Peer Reviewed verified by ORBi

Guérard, S., Lilien, J.-L., & Van Dyke, P. (2009). VIBRATIONS OF A SHORT SPAN, COMPARISON BETWEEN MODELIZATION AND MEASUREMENTS PERFORMED ON A LABORATORY TEST SPAN. In J.-L. Lilien (Ed.), EIght International symposium on Cable Dynamics, ISCD 2009 (pp. 101:114). Liège, Belgium: AIM, rue St Gilles, 31.
Peer reviewed

Guérard, S., van dyke, P., & Lilien, J.-L. (2009). Evaluation of power line cable fatigue parameters based on measurements on a laboratory cable test span. In J.-L. Lilien (Ed.), EIght International symposium on Cable Dynamics, ISCD 2009 (pp. 125:135). Liège, Belgium: AIM, rue St Gilles, 31.
Peer reviewed

Guery, D., Lilien, J.-L., Destiné, J., Gillis, J.-M., Guerard, S., Godard, B., & Libert, T. (2008). Aeolian vibrations on High Voltage Lines .Comparative self damping as evaluated on the field [Paper presentation]. CIGRE (Conférence Internationale des Grands Réseaux Electriques à Haute Tension), Paris, France.
Peer reviewed

Lilien, J.-L., Guerard, S., Godard, B., Destiné, J., & Cloet, E. (2006). Microsystem array for live high voltage lines monitoring [Paper presentation]. CIGRE (Conférence Internationale des Grands Réseaux Electriques à Haute Tension), Paris, France.
Peer reviewed

Lilien, J.-L., Guerard, S., Godard, B., Feiereisen, J.-M., & Destine, J. (2006). Power lines real time monitoring. In S. Y. Zamrik, Proceedings of the 11th ICPVT conference (pp. 8).
Peer reviewed

Renson, L., Jamar, C., Guérard, S., Lilien, J.-L., & Destiné, J. (2005). Array of microsystem for live monitoring of high voltage power lines. In Proceedings of the 1st IOMAC (pp. 8). www.iomac.org.
Peer reviewed

Guérard, S., Gyselinck, J., & Lecomte-Beckers, J. (2005). Finit element modelling of an asynchronous motor with one broken rotor bar, comparison with the data recorded on a prototype and material aspects. Bulletin Scientifique de l'AIM (Association des Ingénieurs Electriciens sortis de l'Institut Electrotechnique Montefiore), 1, 13-22.

Contact ORBi