No full text
Poster (Scientific congresses and symposiums)
Can Increased Instrumental Sensitivity Replace Extensive Sample Preparation?
Bhatt, Kinjal; Gaida, Meriem; Franchina, Flavio et al.
2020HTC 2020
 

Files


Full Text
No document available.

Send to



Details



Keywords :
GC*GC; GAS CHROMATOGRAPHY; SEPARATION SCIENCE
Abstract :
[en] The optimization of gas chromatographic separations is often a necessary step to push the limits of detection and quantitation to their utmost limits. Parameters controlling injection and separation conditions need to be adjusted and optimized thoroughly for rugged and reproducible conditions. Thereby, careful attention needs to be paid to the sample preparation stage, since it often enhances the instrumental sensitivity. Moreover, sample preparation is highly prone to error, as well as time-consuming[1]. For this reason, techniques that offer a reduction of the overall sample preparation procedure are of increasing interest. Two-dimensional comprehensive gas chromatography (GC×GC) offers a wide scope of advantages allowing for simplified sample preparation. For example, analytes of interest can be separated from the interfering matrix due to the increased separation capacity, while the cold zone compression allows for increased sensitivity and improved peak shapes. Especially the hyphenation of GC×GC and highly sensitive mass analyzers can potentially reduce steps needed in existing sample preparation procedures. In this study, the authors evaluate the performance of a GC×GC-ToF/MS for a detailed analysis of the volatile organic profile in Belgian chocolate. To evaluate the impact of the MS’s sensitivity a previously established sample preparation procedure was compared to a minimalistic sample preparation approach [2]. Although the majority of compounds could be determined in both approaches, initial findings indicate differences in between the two investigated approaches. Thereby, the differences are not only limited to the total number of compounds detected but also the detected compound classes differ within the compared approaches. Depending on the analytical challenge, the applied approach has to be chosen. References: [1] R.E. Majors, Overview of Sample Preparation, LCGC. (1991) 16–20. http://www.chromatographyonline.com/overview-sample-preparation. [2] C. Müller, F. Vetter, E. Richter, F. Bracher, Determination of caffeine, myosmine, and nicotine in chocolate by headspace solid-phase microextraction coupled with gas chromatography-tandem mass spectrometry, J. Food Sci. 79 (2014). doi:10.1111/1750-3841.12339.
Research center :
ObiAChem
Disciplines :
Chemistry
Author, co-author :
Bhatt, Kinjal  ;  Université de Liège - ULiège > Département de chimie (sciences) > Département de chimie (sciences)
Gaida, Meriem  ;  Université de Liège - ULiège > Département de chimie (sciences) > Chimie analytique, organique et biologique
Franchina, Flavio ;  Université de Liège - ULiège > Département de chimie (sciences) > Chimie analytique, organique et biologique
Weggler, Benedikt ;  Université de Liège - ULiège > MolSys
Focant, Jean-François  ;  Université de Liège - ULiège > Département de chimie (sciences) > Chimie analytique, organique et biologique
Language :
English
Title :
Can Increased Instrumental Sensitivity Replace Extensive Sample Preparation?
Publication date :
January 2020
Number of pages :
A0
Event name :
HTC 2020
Event place :
GHENT, Belgium
Event date :
FROM 28-01-2020 TO 31-01-2020
Audience :
International
Name of the research project :
CHIMIC
Funders :
EOS - The Excellence Of Science Program [BE]
Available on ORBi :
since 27 January 2020

Statistics


Number of views
120 (25 by ULiège)
Number of downloads
0 (0 by ULiège)

Bibliography


Similar publications



Contact ORBi