[en] Ultra-shallow floor types such as the USFB® and DELTABEAM® beam ‘plug’ composite flooring systems are recently developed and have seen many applications in contemporary construction. They involve partially encased steel beams in concrete, with the lower flange remaining exposed. Besides the satisfactory behavior of the system at ambient conditions, understanding their response to elevated temperatures is critical in evaluating their overall performance. Previous numerical studies of the authors have investigated their fire resistance when simply supported. The computational analyses demonstrated that such flooring systems are experiencing severe thermal gradients and bowing. When such beams are axially restrained, the compression due to the restraining may produce second order effects on the bowed beams. On the other hand, the effect of axial restraints is difficult to be estimated because of the temperature’s non-uniformity across the cross-sections. For this reason, comprehensive finite element analyses (FEA) were implemented in this paper to simulate the response of such restrained beams subjected to fire. Material properties were modelled according to Eurocodes. The coupled thermal-structural parametric analyses involved different variations of the “shortest” cross-sections. From the FE analyses, useful conclusions are drawn.
Disciplines :
Ingénierie civile
Auteur, co-auteur :
Maraveas, Chrysanthos ; Université de Liège - ULiège > Département ArGEnCo > Ingénierie du feu
Fasoulakis, Zacharias
Tsavdaridis, Konstantinos; University of Leeds
Langue du document :
Anglais
Titre :
Fire resistance of axially restrained and partially unprotected Ultra Shallow Floor Beams (USFB®) and DELTABEAM® composite beams
Bailey, C.G. (1999), “The behavior of asymmetric slim floor steel beams in fire”, J. Constr. Steel Res., 50(3), 235–257.
Both, C., Fellinger, J.H.H. and Twilt, L., 1997, Shallow floor construction with deep composite deck: from fire tests to simple calculation rules, Heron, 42(3), 145–158.
Deltabeam Technical Manual, 2013, downloaded from http://www.peikko.com, accessed 19-12-2013. (in Dutch).
Ellobody, E., 2011, Nonlinear behavior of unprotected composite slim floor steel beams exposed to different fire conditions, Thin Wall Struct., 49(6), 762–771.
EN 1991, 2002 Eurocode 1—actions on structures—part 1-2: general actions—actions on structures exposed to fire. CEN Brussels.
EN 1991-1-2, 2002, Eurocode 1: Actions on structures-Part 1-2: General actions – Actions on structures exposed to fire, European Committee for Standardization, Brussels.
EN 1992-1-2, 2004, Eurocode 2: Design of concrete structures-Part 1-2: General rules-Structural fire design, European Committee for Standardization, Brussels.
EN 1993-1-2, 2005. Eurocode 3: design of steel structures — part 1-2: general rules —structural fire design. Brussels: European Committee for Standardisation.
EN 1994-1-1, 2005, Eurocode 4: Design of composite steel and concrete structures-Part 1-1: General rules and rules for buildings, Eu’ropean Committee for Standardization, Brussels.
EN 1994-1-2, 2005, Eurocode4—design of composite steel and concrete structures—part 1-1: design for fire, CEN, Brussels.
Huo B.Y., D’Mello C, Tsavdaridis KD, 2010, Experimental and analytical study of push-out shear tests in ultra-shallow floor beams. In: 34th International association for bridge and structural engineering (IABSE) symposium, Venice, Italy, pp 31–38.
Maraveas, C., 2014, Numerical Analysis of DELTA composite beams in fire, Seventh European Conference on Steel and Composite Structures – EUROSTEEL, Naples, Italy, September.
Maraveas, C., 2018, Fire resistance of delta composite beams: A numerical investigation, Journal of Structural Fire Engineering (Accepted for Publication).
Maraveas, C., Swailes, T. and Wang, Y.C., 2012, A detailed methodology for the finite element analysis of asymmetric slim floor beams in fire, Steel Constr., 5(3), 191–198.
Maraveas, C., Tsavdaridis, K.D. & Nadjai, A., 2017, Fire resistance of unprotected ultra-shallow floor beams (USFB): a numerical investigation, Fire Technol 53, 609–627.
Maraveas, C., Wang, Y.C. and Swailes T., 2014, Fire Resistance of 19th Century fireproof flooring systems: A sensitivity analysis, Constr. Build. Mater., 55, 69–81.
Mäkeläinen, P. and Ma, Z., 2000, Fire resistance of composite slim floor beams, J. Constr. Steel Res., 54(3), 345–363.
Newman, G.M. 1995, Fire resistance of slim floor beams, J. Constr. Steel Res., 33(1-2), 87–100.
Tsavdaridis KD, D’Mello C, Hawes M, 2009, Experimental study of ultra-shallow floor beams (USFB) with perforated steel sections. Nordic Steel Construction Conference 2009, NSCC2009. 2–4 September 2009, Malmo, Sweden, Reference no. 128, pp 312–319.
Tsavdaridis KD, D’Mello C, Huo BY, 2013, Experimental and computational study of vertical shear behaviour of partially encased perforated steel beams. J Eng Struct 56:805–822.
Tsavdaridis KD, Giaralis A, 2011, Derivation of dynamic properties of steel perforated ultra-shallow floor beams (USFB) via finite element modal analysis and experimental verification. The 7th national conference on steel structures, Volos, Greece, vol 2, pp 321–329.
Zaharia, R. and Franssen, J.M., 2012, Simple equations for the calculation of temperature within the cross-section of slim floor beams under ISO fire, Steel Compos. Struct., 13(2), 171–185.