Accuracy and feasibility of contrast echocardiography for detection of perfusion defects in routine practice: comparison with wall motion and technetium-99m sestamibi single-photon emission computed tomography. The Nycomed NC100100 Investigators.
Marwick, T. H.; Brunken, R.; Meland, N.et al.
1998 • In Journal of the American College of Cardiology, 32 (5), p. 1260-9
[en] OBJECTIVES: We sought to assess the feasibility and accuracy of myocardial contrast echocardiography (MCE) using standard imaging approaches for the detection of perfusion defects in patients who had a myocardial infarction (MI). BACKGROUND: Myocardial contrast echocardiography may be more versatile than perfusion scintigraphy for identifying the presence and extent of perfusion defects after MI. However, its reliability in routine practice is unclear. METHODS: Fundamental or harmonic MCE was performed with continuous or triggered imaging in 203 patients with a previous MI using bolus doses of a perfluorocarbon-filled contrast agent (NC100100). All patients underwent single-photon emission computed tomography (SPECT) after the injection of technetium-99m (Tc-99m) sestamibi at rest. Quantitative and semiquantitative SPECT, wall motion and digitized echocardiographic data were interpreted independently. The accuracy of MCE was assessed for detection of segments and patients with moderate and severe sestamibi-SPECT defects, as well as for detection of patients with extensive perfusion defects (>12% of left ventricle). RESULTS: In segments with diagnostic MCE, the segmental sensitivity ranged from 14% to 65%, and the specificity varied from 78% to 95%, depending on the dose of contrast agent. Using both segment- and patient-based analysis, the greatest accuracy and proportion of interpretable images were obtained using harmonic imaging in the triggered mode. For the detection of extensive defects, the sensitivity varied from 13% to 48%, with specificity from 63% to 100%. Harmonic imaging remained the most accurate approach. Time since MI and SPECT defect location and intensity were all determinants of the MCE response. The extent of defects on MCE was less than the extent of either abnormal wall motion or SPECT abnormalities. The combination of wall motion and MCE assessment gave the best balance of sensitivity (46% to 55%) and specificity (82% to 83%). CONCLUSIONS: Although MCE is specific, it has limited sensitivity for detection of moderate or severe perfusion defects, and it underestimates the extent of SPECT defects. The best results are obtained by integration with wall motion. More sophisticated methods of acquisition and interpretation are needed to enhance the feasibility of this technique in routine practice.
Disciplines :
Cardiovascular & respiratory systems
Author, co-author :
Marwick, T. H.
Brunken, R.
Meland, N.
Brochet, E.
Baer, F. M.
Binder, T.
Flachskampf, Frank
Kamp, O.
Nienaber, C.
Nihoyannopoulos, Petros
Pierard, Luc ; Université de Liège - ULiège > Département des sciences cliniques > Cardiologie - Pathologie spéciale et réhabilitation
Accuracy and feasibility of contrast echocardiography for detection of perfusion defects in routine practice: comparison with wall motion and technetium-99m sestamibi single-photon emission computed tomography. The Nycomed NC100100 Investigators.
Ladenheim ML, Kotler TS, Pollock BH, Berman DS, Diamond GA. Incremental prognostic power of clinical history, exercise electrocardiography and myocardial perfusion scintigraphy in suspected coronary artery disease. Am J Cardiol 1987;59:270-7.
Machecourt J, Longere P, Fagret D, et al. Prognostic value of thallium-201 single photon emission computed tomographic myocardial perfusion imaging according to extent of myocardial defect. J Am Coll Cardiol 1994;23: 1096-106.
Gibson RS, Watson DD, Craddock GB, et al. Prediction of cardiac events after uncomplicated myocardial infarction: a prospective study comparing predischarge exercise thallium-201 scintigraphy and coronary angiography. Circulation 1983;68:321-36.
Radensky PW, Hilton TC, Fulmer H, McLaughlin BA, Stowers SA. Potential cost effectiveness of initial myocardial perfusion imaging for assessment of emergency department patients with chest pain. Am J Cardiol 1997;79: 595-9.
Abbottsmith CW, Topol EJ, George BS, et al. Fate of patients with acute myocardial infarction with patency of the infarct-related vessel achieved with successful thrombolysis versus rescue angioplasty. J Am Coll Cardiol 1990; 16:770-8.
TIMI Study Group. Comparison of invasive and conservative strategies after treatment with intravenous tissue plasminogen activator in acute myocardial infarction: results of the Thrombolysis in Myocardial Infarction (TIMI) phase II trial. N Engl J Med 1989;320:618-26.
Miller TD, Christian TF, Hopfenspirger MR, Hodge DO, Gersh BJ, Gibbons RJ. Infarct size after acute myocardial infarction measured by quantitative tomographic 99mTc sestamibi imaging predicts subsequent mortality. Circulation 1995;92:334-41.
Schiller NB, Shah PM, Crawford M, et al. Recommendations for quantitation of the left ventricle by two-dimensional echocardiography: American Society of Echocardiography Committee on Standards, Subcommittee on Quantitation of Two-Dimensional Echocardiograms. J Am Soc Echocardiogr 1989;2:358-67.
Friedman J, Berman DS, Van Train K, et al. Patient motion in thallium-201 myocardial SPECT imaging: An easily identified frequent source of artifactual defect. Clin Nucl Med 1988;13:321-4.
DePuey EG, Garcia EV. Optimal specificity of thallium-201 SPECT through recognition of imaging artifacts. J Nucl Med 1989;30:441-9.
Block RJ, Brodsky L, Ostoic T, et al. Optimizing albunex in the left ventricle: an analysis of the technical parameters of four ultrasound systems in canines and humans. J Am Soc Echocardiogr 1996;9:787-94.
Bach DS, Muller DW, Cheirif J, Armstrong WF. Regional heterogeneity on myocardial contrast echocardiography without severe obstructive coronary artery disease. Am J Cardiol 1995;75:982-6.
Kaul S, Senior R, Dittrich H, Raval U, Khattar R, Lahiri A. Detection of coronary artery disease with myocardial contrast echocardiography: comparison with 99mTc-sestamibi single-photon emission computed tomography. Circulation 1997;96:785-92.
Porter TR, Xie F, Kricsfeld A, Deligonul U, Kilzer K. Reduction in left ventricular cavitary attenuation and improvement in posterior myocardial contrast with higher molecular weight intravenous perfluorocarbon-exposed sonicated dextrose albumin microbubbles. J Am Soc Echocardiogr 1996;9: 437-41.
Vandenberg BF, Melton HE. Acoustic lability of albumin microspheres. J Am Soc Echocardiogr 1994;7:582-9.
Kaul S. Clinical applications of myocardial contrast echocardiography. In: Braunwald E, editor. Heart Disease: A Textbook of Cardiovascular Medicine (Update 1). Philadelphia: W.B. Saunders, 1997:304-13.
Parodi P, Schelbert HR, Schwaiger M, et al. Cardiac emission computed tomography: underestimation of regional tracer concentrations due to wall motion abnormalities. J Comput Assist Tomogr 1984;8:1083-9.
Mor-Avi V, Lang RM, Robinson KA, et al. Contrast echocardiographic quantification of regional myocardial perfusion: validation with an isolated rabbit heart model. J Am Soc Echocardiogr 1996;9:156-65.
Meza MF, Mobarek S, Sonnemaker R, et al. Myocardial contrast echocardiography in human beings: correlation of resting perfusion defects to sestamibi single photon emission computed tomography. Am Heart J 1996;132:528-35.
Porter TR, Li S, Kricsfeld D, Armbruster RW. Detection of myocardial perfusion in multiple echocardiographic windows with one intravenous injection of microbubbles using transient response second harmonic imaging. J Am Coll Cardiol 1997;29:791-9.