Publications of Séverine CUCCHIARO
Bookmark and Share    
Full Text
See detailThe Influence of Treatment Position (Prone vs. Supine) on Clip Displacement, Seroma, Tumor Bed and Partial Breast Target Volumes: Comparative Study
Lakosi, Ferenc; GULYBAN, Akos ULiege; BEN MUSTAPHA, Selma ULiege et al

in Pathology Oncology Research (2016), 22(3), 493-500

To analyse the displacement of surgical clips in prone (Pr) position and assess the consequences on target volumes and integral dose of partial breast irradiation (PBI). 30 post-lumpectomy breast cancer ... [more ▼]

To analyse the displacement of surgical clips in prone (Pr) position and assess the consequences on target volumes and integral dose of partial breast irradiation (PBI). 30 post-lumpectomy breast cancer patients underwent CT imaging in supine (Su) and Pr. Clip displacements were measured by the distances from the clips to a common fix bony reference point. On each dataset, the tumour bed (TB = clips ± seroma), clinical target volume (CTV = TB + 1.5 cm) and planning target volumes (PTV = CTV + 1 cm) for PBI were determined and the volume pairs were compared. Furthermore estimation of integral dose ratio (IDR) within the breast from tangential treatment was performed as the ratio of the irradiated breast volume and the volume encompassing all clips. Clips close to the chest wall (CW) in Su showed significantly less displacement in Pr. The mean volumes of seroma, CTV and PTV were significantly higher in Pr than in Su. The PTV volume difference (Pr-Su) was significantly higher in patients with presence of seroma, deep clips and TB location in the superior-internal-quadrant (SIQ) and at the junction of superior quadrants (jSQ). In a multivariate analysis two factors remained significant: seroma and TB localization in SIQ-jSQ. The IDR was significantly larger in Su than in Pr (7.6 vs. 4.1 p < 0.01). Clip displacements varied considerably with respect to their relative position to the CW. In selected patients Pr position potentially leads to a significant increase in target volumes of PBI. Tangential beam arrangement for PBI should be avoided, not only in Su but in Pr as well in case of clip-based target volume definition. [less ▲]

Detailed reference viewed: 56 (8 ULiège)
Full Text
See detailAnalysis of polychlorinated biphenyl residues in human plasma by gas chromatography-mass spectrometry
Charlier, Corinne ULiege; Dubois, Nathalie ULiege; CUCCHIARO, Séverine ULiege et al

in Journal of Analytical Toxicology (2003), 27(2), 74-77

A method for the determination of seven polychlorinated biphenyl residues in plasma by gas chromatography-mass spectrometry was developed. The analytes were isolated from human plasma by liquid-liquid ... [more ▼]

A method for the determination of seven polychlorinated biphenyl residues in plasma by gas chromatography-mass spectrometry was developed. The analytes were isolated from human plasma by liquid-liquid extraction, followed by solid-phase extraction, and separation on an HP5 Trace column. Ionization mode was electronic impact, and selected ion storage was used for isolation and quantitation of the compounds. The method was evaluated for its analytical performances and therefore applied to monitor the prevalence of these seven polychlorinated biphenyl residues in a female population. Eighty samples were analyzed, and 82.5% presented detectable amounts of at least one residue. For the population study, results were reported on a lipid-adjusted basis. Because the proposed method is satisfying and seems to be suitable for the quantitation of PCB congeners in a general population, epidemiological studies to evaluate the widespread contamination with these environmental compounds can be proposed. [less ▲]

Detailed reference viewed: 58 (13 ULiège)